![Datalogic DS2400N Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/datalogic/ds2400n/ds2400n_reference-manual_511874047.webp)
INSTALLATION
3
max 2 m
DS2400N
# x
(up to 31)
DS2400N
# 1
DS2400N
# 0
RTX485 -
RTX485 -
Three wires +
shield
120 Ohm
120 Ohm
CHASSIS
SGND
ma
x 1200
m
RS485 REF
SHIELD
MULTIPLEXER
Figure 22 - DS2400N Multidrop Connection to a Multiplexer
20 mA Current Loop Interface
(C-Box 100 w/INT-30 Accessory Only)
To adapt DS2400N to 20 mA current loop interfaces, it must be connected to a
C-Box 100, which is equipped with an INT-30 (20 mA current loop adapter accessory
board).
The INT-30 converts 20 mA current loop signals into RS232 signals to the scanner.
See the C-Box 100 Installation Manual and the INT-30 instructions.