DS2400N
1
C-BOX 100/150 Pinout for DS2400N
The table below gives the pinout of the C-BOX 100/150 terminal block connectors.
Use this pinout when the DS2400N reader is connected in a network by means of the
C-BOX 100/150:
C-BOX 100/150 Terminal Block Connectors
Power
Outputs
1, 3, 5
VS
21
OUT 1+
2, 4, 6
GND
22
OUT 1-
7, 8
EARTH GROUND
23
OUT 2+
20, 40
Reserved
24
OUT 2-
Inputs
25 NC
27
EXT TRIG A (polarity
insensitive)
26 NC
28
EXT TRIG B (polarity
insensitive)
Auxiliary Interface
29 NC
35 TX
AUX
30 IN2-
37 RX
AUX
31, 33
NC
ID-NET™
32, 34
NC
36
ID-NET-
39 GND
38 ID-NET+
Main Interface
RS232
RS485 Full-
Duplex
RS485 Half-Duplex
20 mA C.L.
(with INT-30 only)
11, 15
TX 232
TX 485+
RTX 485+
12, 16
RTS 232
TX 485-
RTX 485-
17
RX 232
RX 485+
18 CTS
232 RX
485-
10, 14,
19
SGND SGND
SGND
9, 13
RS485 Cable
Shield
RS485 Cable Shield
see INT-30
instructions
CAUTION
Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.
2
Содержание DS2400N
Страница 1: ...DS2400N REFERENCE MANUAL ...
Страница 5: ...GLOSSARY 70 INDEX 74 v ...
Страница 10: ...x ...
Страница 20: ...DS2400N 1 b Operating mode selection and definition c Digital Outputs configuration 10 ...
Страница 49: ...INSTALLATION 3 Figure 23 ID NET Network Connections with isolated power blocks 39 ...
Страница 50: ...DS2400N 3 Figure 24 ID NET Network Connections with Common Power Branch Network 40 ...
Страница 51: ...INSTALLATION 3 Figure 25 ID NET Network Connections with Common Power Star Network 41 ...