![Datalogic DS2400N Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/datalogic/ds2400n/ds2400n_reference-manual_511874043.webp)
INSTALLATION
3
RS232 Interface
The serial interface is used in this case for point-to-point connections; it handles
communication with the host computer and allows both transmission of code data
and the programming of the scanner. This is the default setting.
The following pins are used for RS232 interface connection:
Pin Name
Function
2 TX232
transmit
data
3 RX232
receive
data
4
RTS232
request to send
5
CTS232
clear to send
7 SGND
signal
ground
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
DS2400N
7
4
5
3
SGND
RTS232
CTS232
RX232
TX232
2
USER INTERFACE
SGND
DCD
DTR
TXD
RXD
1
Chassis
Figure 18 – RS232 Main Interface Connections using Hardware Handshaking
The RTS232 and CTS232 signals control data transmission and synchronize the
connected devices.