3.3 ELECTRICAL
CONNECTIONS
All DS2400N models are equipped with a cable terminated by a 25-pin female D-sub
connector for connection to the power supply and input/output signals.
The details of the connector pins are indicated in the following table:
CAUTION
Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.
13
1
14
25
Figure 16 - 25-pin Female D-sub Connector
25-pin D-sub female connector pinout
Pin Name
Function
13, 9
VS
Power supply input v
25
GND
Power supply input voltage -
1
CHASSIS
Cable shield connected to chassis
18
EXT TRIG A
External Trigger A (polarity insensitive)
19
EXT TRIG B
External Trigger B (polarity insensitive)
10 IN2
-
Input
2
-
8 OUT1
+
Output
1
+
22 OUT1
-
Output
1
-
11
OUT2 +
Output 2 +
12 OUT2
-
Output
2
-
20 RXAUX
Auxiliary
RS232
21 TXAUX
Auxiliary
RS232
23
ID-NET +
High speed internal n
24
ID-NET -
High speed interconnection network -
6, 10, 14, 15,
16, 17
NC Not
Connected
Pin Name
RS232
RS485
Full-Duplex
RS485
Half-Duplex
2 TX232
TX485+
3 RX232
RX485+
4 RTS232
TX485-
RTX485-
5 CTS232
RX485-
7
MAIN INTERFACE
(SW SELECTABLE)
SGND SGND
SGND
30
Содержание DS2400N
Страница 1: ...DS2400N REFERENCE MANUAL ...
Страница 5: ...GLOSSARY 70 INDEX 74 v ...
Страница 10: ...x ...
Страница 20: ...DS2400N 1 b Operating mode selection and definition c Digital Outputs configuration 10 ...
Страница 49: ...INSTALLATION 3 Figure 23 ID NET Network Connections with isolated power blocks 39 ...
Страница 50: ...DS2400N 3 Figure 24 ID NET Network Connections with Common Power Branch Network 40 ...
Страница 51: ...INSTALLATION 3 Figure 25 ID NET Network Connections with Common Power Star Network 41 ...