![Datalogic AMT58-PB Series Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/datalogic/amt58-pb-series/amt58-pb-series_instruction-manual_512524086.webp)
AMT58x-PB Profibus®
31
6.7 DDLM_Slave_Diag
The Master device can send a request for diagnostic information at
any time to the Slave device.
Datalogic devices provide two types of diagnostics:
- reduced (16 bytes)
- extended (63 bytes).
Set the diagnostic type during DDLM_Set_Prm, operating
parameters (byte 10), see section “6.4.1 Byte 10 - Operating
parameters”.
16-byte Diagnostic:
Byte Description
Byte Description
0
Status 1
8
Operating status
1
Status 2
9
Encoder type
2 Status
3 10
Hardware single-turn
resolution
3 Master
ID 11
4
Manufacturer ID
12
5 13
6
Extended diagnostic
header
14
Hardware number of
revolution
15
7 Alarms
63-byte Diagnostic:
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]