4.2 Ground connection
Minimize noise by connecting the shield and/or the connector
housing and/or the frame to ground. Make sure that ground is not
affected by noise. The connection point to ground can be situated
both on the device side and on user’s side. The best solution to
minimize the interference must be carried out by the user. You are
advised to provide the ground connection as close as possible to the
encoder. We suggest using the ground point provided in the cap (see
Figure, use 1 TCEI M3 x 6 cylindrical head screw with 2 tooth lock
washers).
4.3 Connection cap with PGs (Figure 1)
Figure 1
Connection cap is fitted with three PG9 cable glands for bus-IN, bus-
OUT connections as well as power supply connection. The bus
cables can be connected directly to the terminal connectors located
in front of each cable gland.
We recommend Profibus-DP certificated cables to be used. Core
diameter should not exceed Ø 1,5 mm (0.06 inch).
Terminal connector
Description
-
0 VDC Supply voltage
+
+10VDC +30VDC Supply
voltage
B
Profibus B (Red)
A Profibus
A
(Green)
PG
Shield
1
1
Connect the cable shield to cable gland.