6.4 DDLM_Set_Prm
When system is turned on, configuration data set by the operator is
sent to the absolute encoder by the controller. Parameters
transmission depends on the configuration chosen by the operator.
Customarily data is sent automatically while data setting is carried
out through a user's interface available in the controller's software
(for instance, STEP7, see section “5.1 STEP7 configuration”)
However sometimes it is necessary to set some bits and bytes
according to the working specifications you want to set.
Data transmission is carried out in compliance with values set for the
encoder profile and shown in the following tables.
DDLM_Set_Prm with Class 1:
Byte
Parameter
0…9
Reserved for PROFIBUS network
10
Operating
parameters
bit 0
Code sequence
bit 1
Class 2 functionality
bits2…5 Reserved
bit 6
Diagnostic type
bit 7
Exchange type
11…20
Reserved
DDLM_Set_Prm with Class 2:
Byte
Parameter
0…9
Reserved for PROFIBUS network
10
Operating
parameters
bit 0
Code sequence
bit 1
Class 2 functionality
bit 2
Reserved
bit 3
Scaling function control
bits 4, 5
Reserved
bit 6
Diagnostic type
bit 7
Exchange type
11…14
Counts per revolution
15…18
Total resolution
19…20
Reserved