Use the Setup menu to access the communications options. Select the options as shown in Figure
11, replacing the Serial Port setting with the correct port. Uncheck the Enable Processor Verification
option if you have problems connecting, and check the Use USB to Serial Converter option if
appropriate. If problems persist, try setting the Stop Bits to 1.
Figure 11
– RFU Communications Options
Use the File/Load flash image menu to select and send the firmware data. Contact Datalink to obtain
firmware update files.
Note: the programmer may not work reliably when using a USB to serial converter connected
through a USB hub or via USB 3.0 ports. If you have problems, try a different converter brand,
or use a PC with built-in serial port.