i50 Manual (5.51)
Page 27
© 2018 Datalink Systems, Inc.
www.datalinksystemsinc.com
7.2.1 Programmer Toolbar
Open Port:
Open PC COM port. Use the Connection/Select Port menu to
select the desired port.
Reboot:
Attempt to reboot the i50. This will only work if the PC is
connected to the i50 Program connector (RJ-45).
Start Device:
Instruct the i50 to exit programming mode and begin normal
operation. The programmer will close the COM port at this
stage to prevent sending data to the i50.
Close Port:
Close PC COM port.
Device Ports:
Open the Ports window. See section 7.4.
Test :
Open the Test window. See section 7.5.
Set Clock:
Set the i50 Real Time Clock (RTC) to match the PC’s clock.
Note that the programmer determines the time in UTC format so
that it is written correctly no matter what time zone the PC is in.
Reset Accel:
Cause the i50 to automatically calibrate its accelerometer. A
short list of instructions is shown to assist in the calibration.
Get Buffer:
Retrieves any packets in i50 memory and saves to disk.
Clear Buffer:
Clears all position and event packets from the i50 buffer. Note
that the i50 will send a special event to indicate that its buffer
has been cleared.
7.2.2 Factory Reset
With firmware version 5.32 or later, it is possible to delete all settings and data on the i50 using the
Device/Factory Reset menu. This can be useful if the settings password has been forgotten, as it will
delete the password and return all settings to their default values.