i50 Manual (5.51)
Page 28
© 2018 Datalink Systems, Inc.
www.datalinksystemsinc.com
7.2.3 Settings
Double-click on a setting to modify its value. See section 17.0 for default values. The following
settings are supported (some may not be available or supported, depending on i50 firmware version):
Identification
Asset ID:
ID (0.0.0 to 255.255.255), used to identify unit on server.
Settings Password:
If a password is entered, the iSeries Programmer will request a
password before allowing users to read or write settings.
Available in firmware 5.32 or later.
Counters
Engine Hours:
Accumulated engine hours counter.
Odometer:
Accumulated odometer reading.
Fuelmeter:
Accumulated fuel used.
Sleep Mode
Sleep Pin:
Selects which pin (and polarity) will be monitored to put unit into
sleep mode. On power up, normal behaviour is to go straight
into sleep mode if the sleep pin is active. However, there is also
a “Wake at boot” option to enter periodic wakeup mode when
power is applied. The “Wake on motion” option causes the unit
to wake up when motion is detected.
Sleep Timeout:
Delay after sleep pin activated (and motion stops, if the “Wake
on motion” option is set under the “Sleep Pin” setting) before
unit enters sleep mode. Set to zero to disable sleep mode.
Periodic Wakeup:
While sleeping, the unit can wake periodically to send its
location. Set to zero to disable periodic wakeups.
Max GPS Wait Time:
Max time to wait for valid GPS signal during a periodic wakeup.
Max Send Wait Time:
Max time to wait for modem to go online and send data when
entering sleep mode.
Input Pins
Report IGN:
Select whether to send events when IGN line changes state.
Debounce IGN:
Time required to trigger an IGN change.
Report Input 1-4:
Select whether to send events when input lines change state.
Debounce Input 1-4:
Time required to trigger an input change.
Input 1-4:
Select input type. See section 15.0 for more information.
Input 1-4 Polarity:
Select polarity of input signals.
ADC1-2 High Voltage:
Trigger event when ADC voltage exceeds this level.
ADC1-2 Low Voltage:
Trigger event when ADC voltage drops under this level.
Debounce ADC1-2:
Time required to trigger an ADC change.
Output Pins
Output 1-4:
Select output type. See section 15.0 for more information.
Output 1-4 Polarity:
Polarity for output signals. For General Outputs, the polarity
defines the current output state (high or low).
VOUT Function:
Controls behaviour of VOUT pin.
VOUT Polarity:
VOUT polarity when using VOUT as an output signal.