DK-40 USER MANUAL V2.6 (02.08.2011)
K13D01-E - 26 -
No
Description
Adjustment Range
Factory set
P27
Unload timer fixed or
variable
0
: Fixed
1
: Variable
If set to 1:
If the stop duration is more than
the unload run duration, the
unload timer is reduced by 1
minute at each run, until an
absolute minimum of 2 minutes.
0
P28
Safety Timer
1 ... 240
Refer to chapter 4 for this
parameter.
30 sec
P29
Service A Period
0 ... 32767
If this parameter is set to
0
, then
no service A warning is given.
2000 hours
P30
Service B Period
0 ... 32767
If this parameter is set to
0
, then
no service B warning is given.
4000 hours
P31
Service C Period
0 ... 32767
If this parameter is set to
0
, then
no service C warning is given.
6000 hours
P32
Service D Period
0 ... 32767
If this parameter is set to
0
, then
no service D warning is given.
14000 hours
P33
Service E Period
0 ... 32767
If this parameter is set to
0
, then
no service E warning is given.
20000 hours
P34
Display Extra sensors
0
: Disable
1
: Enable
1
P35
Low level password
0 ... 999
386
P36
High level password
0 ... 999
741
P37
Maximum Starts per Hour
6 ... 60
20
P38
Low Voltage Alarm Enable
0
:Disable
1
:Enable
If this parameter is set to
0
, the
P39 parameter will not be
displayed.
1
P39
Low Voltage Alarm Value
200 ... 600
360 V-AC