D-200 MK2 User Manual Firmware V-6.3
L058D01-EN - 60 -
The RUN mode is entered by pressing the
button.
When the RUN mode is selected, the engine will be started regardless of the mains availability.
The starting sequence is as described below:
•
The unit turns on the fuel and preheat glow plugs (if any) and waits for preheat timer.
•
The engine will be cranked for programmed times during crank timer. When the engine fires, the
crank relay will be immediately deactivated. See section
Crank Cutting
for more details.
•
The engine will run at idle speed during Idle Speed Timer.
•
The engine will run unloaded until another mode is selected..
•
The load can be transferred to the genset by selecting TEST mode.
In order to stop the engine press
button or select another mode of operation.
The TEST mode is entered by holding pressed the
button for 5 seconds.
The TEST mode is used in order to test the genset under load.
Once this mode is selected, the engine will run as described in the AUTO mode, regardless of the mains
availability and the load will be transferred to the genset.
The genset will feed the load indefinitely unless another mode is selected.
13.5. TEST MODE
If Emergency Backup mode is enabled and if the mains are
off, then the mains contactor will be deactivated and the
generator contactor will be activated.
When the mains are on again, a reverse changeover to the
mains will be performed, but the engine will keep running
unless another mode is selected.
If uninterrupted transfers are allowed, then the unit will check
the synchronization. If synchronization is complete, then it will
make an uninterrupted transfer, where both contactors will be on
for a short while.
13.4. RUN MODE
Содержание D-200 MK2
Страница 30: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 30 4 3 3 PHASE 3 WIRE DELTA 4 2 3 PHASE 4 WIRE STAR ...
Страница 33: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 33 4 9 1 PHASE 2 WIRE 4 8 2 PHASE 3 WIRE DELTA 2 CTs L1 L3 ...
Страница 38: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 38 6 2 AMF FUNCTIONALITY CTs AT ALTERNATOR SIDE ...
Страница 39: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 39 6 3 ATS FUNCTIONALITY ...
Страница 40: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 40 6 4 REMOTE START FUNCTIONALITY ...
Страница 41: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 41 6 5 ENGINE CONTROL FUNCTIONALITY ...
Страница 42: ...D 200 MK2 User Manual Firmware V 6 3 L058D01 EN 42 Feature not applicable to this product 6 6 ...