85
© 2010 Datacom Systems Inc
Appendix 2 - Sample Filter Setup
VERSA
™
stream
3. Agent > Connect —
Connect to the FLOW
control
™ Agent
previously added to the Agent List by navigating to,
highlighting the IP address and either double-click the IP
address or use the Agent > Connect menu to open the dialog
box requesting authentication information for the selected
agent.
4. Port Configuration —
Change
Port Names
that are
meaningful to the user. Select
Media Preference
(copper/
fiber) and
Port Speed Setting
according to the port connected
product. Assign a
Port Type,
Network Port
or
Monitor Port
(this is just a label where
Network Port indicates an input
port) and this setting does not
affect packet traffic or
aggregation. When all
selections have been
completed, click the
Apply
Selections
button.
5. Aggregation Configuration —
Determines how you are steering traffic within
the FVS-1080 from data coming into the product to specific monitoring ports. In
this example, recall that there
are six input streams coming in
on Port 1 through Port 6. Go to
the ports that are used as
monitoring ports. Check the
boxes that traffic is to be
received from. Now we will
select Port 1, Port 2 and Port 3
to go out Port 7 aggregated and
Port 4, Port 5 and Port 6 to go
out Port 8 aggregated. (
Note
:
This selection is egress focused
or directed toward traffic
leaving the product.) Click the
Apply
button.