Datacolor Conditioner Operation Manual / DCCOPMN_RP1 / Rev 3.0 / 7th August 07
page 8 of 51
1.4 Intended
use
Datacolor CONDITIONER™ sample conditioning cabinets are designed for exact conditioning of
harmless materials. A mixture of any component of the charging material mixed with air must NOT be
explosive. The operating temperature must lie below the flash point or below the sublimation point of the
charging material.
Respecting the instructions in this operation manual and conducting regular maintenance
work (chap. 11) is part of the intended use.
2. Unit
description
Datacolor CONDITIONER™ sample conditioning cabinet with controller RP1 is available in two different
types:
•
with lighting unit
•
without lighting unit
Datacolor CONDITIONER™ is designed for exact conditioning of harmless materials such as paper,
textiles, plastics, building materials, to condition the samples at fixed temperature and humidity, so as
ensure no change in color of the samples occurs due to varying temperature and humidity
The inner chamber, the pre-heating chamber and the inside of the doors are all made of stainless steel
(material no. 1.4301 in Germany). The housing is RAL 7035 powder-coated. All corners and edges are
completely coated.
The inner chamber is closed by a glass door that enables the samples to be viewed for a short time
without disturbing the climate in the inner chamber.
Datacolor CONDITIONER™ is equipped with a microprocessor controller with 2-channel technology for
temperature and humidity and a digital display accurate to one-tenth of a degree resp. 0.1 % RH
With its microprocessor controlled humidifying and dehumidifying system the Datacolor
CONDITIONER™ is a high-precision sample conditioning cabinet. An electrode steam humidifying
system humidifies the air. There are no special demands on water quality; only the conductivity of the
water is significant (chapter 4.1).