W a r r a n t y

Data Industrial Corporation (“Seller”) of 11 Industrial Drive, Mattapoisett, Massachusetts 02739-0740, U.S.A.,
warrants to the original purchaser of its product that such product manufactured by Data Industrial Corpo-
ration shall be free from defects in materials or workmanship when installed, serviced and operated ac-
cording to Data Industrial Corporation instructions or in other such normal use. This warranty is effective
for a period of 12 months from the date of installation by the Purchaser or 18 months from the date of
shipment by the “Seller” whichever occurs or terminates first. This limited warranty does not cover damage
or loss resulting from corrosion or erosion caused by acids or other chemicals or by severe environmental
conditions or negligent or improper installation or improper operation, misuse, accident, unauthorized
repair or substitution of components other than those provided by the “Seller”, and does not cover limited
life components such as bearings, shafts, impellers where wear rate is a function of application and envi-
ronment.  Any component not manufactured by the “Seller” but included in its products shall not be cov-
ered by this warranty and is sold only under such warranty as the manufacturer may provide.

If Buyer or Purchaser wishes to make a claim hereunder, he shall send written notice of any defect within
the warranty period, to “Seller” at the above address.  “Seller” may at its sole option instruct Buyer to ship
subject part, postage prepaid, to the “Seller” at above address or authorize a representative to inspect the
part on site.  “Seller” will at its sole option repair or replace any defective product covered by this warranty.
If Buyer makes repairs or alterations to any product or part covered by this warranty without “Sellers” prior
written approval, this warranty shall be null and void.

The foregoing shall constitute Buyers or Purchasers sole and exclusive remedy against “Seller”, and no
other remedy, including but not limited to, incidental or consequential damages for personal injury, loss of
fluids, gases or other substances or for loss of profits or injury to property or person shall be available to
the Buyer or Purchaser.  The warranty extended herein shall be in lieu of any other implied warranty of
merchantability or fitness for a particular purpose, and seller shall bear no liability for representatives or
retail sellers.  In no event shall Data Industrial Corporation be liable for any contingent, incidental, or
consequential damage or expenses due to partial or complete inoperability of its product.

All rights reserved.  No part of this work covered by the copyrights hereon may be reproduced or copied
in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording,
taping, or information and retrieval systems -- without written permission of Data Industrial.

Copyright © 2001
Data Industrial Corporation
11 Industrial Drive
Mattapoisett, MA  02739
TEL: 508-758-6390
FAX: 508-758-4057
email:

[email protected]
[email protected]

web site: www.dataindustrial.com

Содержание 340 Series

Страница 1: ...puter real time flow rate flow total both temperature readings energy rate and energy total are available The Series 340 transmitter features two LED s to verify input and output signals The standard output for the Series 340 is an isolated solid state switch closure that is user programmed for units of energy or flow The output pulse width is adjustable from 50 mS to 5 sec The Series 340 Btu tran...

Страница 2: ...ment of the programming cable The unit generates very little heat so no consideration need be given to cooling or ventilation Surface Mount Installation The 340 may be mounted to the surface of any panel using double sided adhesive tape or by attaching fasteners through the holes in the mounting flanges of the unit Din rail Mounting Optional clips snap onto the mounting flanges allowing the 340 to...

Страница 3: ...is used connect the black white striped wire to the terminal marked positive and the black wire to the terminal marked negative Note Included with every Series 340 is a 340IK kit containing a screw lock washer and nut to connect the Series 340 to Earth Ground Connect the Earth Ground Lug of the Series 340 to a solid Earth Ground with as short a wire as possible This will help prevent electrical in...

Страница 4: ...rve the electrical polarity of the output Communications cable wiring Field calibration requires a Data Industrial A340 Programming kit consisting of a custom cable and software and a PC running Windows 9x ME NT or 2000 In order to calibrate the Series 340 must be connected to power and the A301 cable must be connected to the 340 Comm port connector and an available 9 pin COM port on a computer No...

Страница 5: ...ustrial A 301 communications cable to the socket labeled D I C Comm Port taking care to properly align the tab on the plug and socket to maintain polarity Connect the DB9 connector of the Data Industrial A301 communications cable to a PC com port that has the 340 software installed 3 Connect the Series 340 transmitter to a power supply 4 Open the interface software and select the appropriate COM P...

Страница 6: ...ed with 10 providing the greatest degree of smoothing See the Dialog Box below 6 Program using diagram below as a reference Step 1 see note 1 Select the flow sensor type sine or pulse and enter the k and offset Step 4 Select the desired flow rate and total units here Step 7 Press send to transmit calibration data to the 340 Step 5 Select the desired energy rate and total units here Step 2 Select t...

Страница 7: ...ce Opto isolated solid state switch Operating Voltage range 0 60V DC or AC peak Closed on state Load Current 700mA max over operating temperature range On resistance 700mΩ max over operating temperature range Open off state leakage 70 C 1 A 60V DC or AC peak Operating Temperature 29 C to 70 C 20 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F Weight 4 8 oz With headers installed SENSOR C...

Страница 8: ... a Version n a Temperature Units F Sensor Type Pulse K 1 offset 0 Flow Rate Units gpm Flow Total Units gallons Energy Rate Units kBtu hr Energy Total Units Btu Energy Calculation absolute Flow Filter 0 Energy Filter 0 Scaled Pulse Output Units energy Scaled Pulse Output Units Per Pulse 1 Scaled Pulse Output Pulse Width 100 ...

Страница 9: ...ress Seller may at its sole option instruct Buyer to ship subject part postage prepaid to the Seller at above address or authorize a representative to inspect the part on site Seller will at its sole option repair or replace any defective product covered by this warranty If Buyer makes repairs or alterations to any product or part covered by this warranty without Sellers prior written approval thi...