The System Command
108
DD400 Series Restorer User Guide
Display System Status
The system hardware status display includes information about the NVRAM card, internal
temperatures, the state of power supplies, and CPU speed.
•
NVRAM Card
-
The
memory size
,
window size
, and
number batteries
identify the type of NVRAM card.
-
The
errors
entry shows the operational state of the card. If the card has one or more PCI or
memory errors, an alerts email is sent and the daily AM-email includes an NVRAM entry.
-
Each
battery
entry should show
100% charged, enabled
. The exceptions are for a new
system or for a replacement NVRAM card. In both cases, the charge may initially be
below 100%. If the charge does not reach 100% in three days (or if a battery is not
enabled), the card should be replaced.
•
Temperature Measurements
-
If the overall temperature for a restorer reaches 47 degrees centigrade, a warning message
is generated. If the temperature reaches 50 degrees centigrade, the restorer shuts down.
-
If a CPU temperature reaches 60 degrees centigrade, a warning message is generated. If a
CPU temperature reaches 74 degrees centigrade, the restorer shuts down.
•
The message about power supplies informs you that all power supplies are either operating
normally or that one or more are not operating normally. The message does not identify which
power supply or supplies are not functioning. Look at the back panel of the restorer and check
the LED for each power supply to identify those that need replacement.
•
CPU Speed Check
appears only in the command line interface, not in the DDR Manager. The
check shows whether or not CPU temperature is affecting CPU speed. The check shows two
hyper-threaded virtual CPUs for each actual CPU.
Display
To display the current hardware status, such as processor vital signs, internal temperatures, and
power supply output, use the
system status
operation.
system status
The display is similar to the following:
#
system status
NVRAM Card:
component value
---------------- ---------------------
memory size 512 MB
window size 16 MB
number batteries 2
errors 0 PCI, 0 memory
Содержание DD400 Series
Страница 1: ...Software Version 3 1 2 DD400 Series Restorer User Guide ...
Страница 4: ......
Страница 18: ...xviii DD400 Series Restorer User Guide replication 237 route 245 snmp 247 system 250 user 256 Index 257 ...
Страница 38: ...Regulatory Standards Compliance xxxviii DD400 Series Restorer User Guide ...
Страница 54: ...Hardware System Level Interfaces 16 DD400 Series Restorer User Guide ...
Страница 60: ...Display the Space Usage Graphs 22 DD400 Series Restorer User Guide ...
Страница 96: ...The License Command 58 DD400 Series Restorer User Guide ...
Страница 102: ...Return Command Output to a Remote machine 64 DD400 Series Restorer User Guide ...
Страница 128: ...Clean Operations 90 DD400 Series Restorer User Guide ...
Страница 138: ...Display the History of Disk Failures 100 DD400 Series Restorer User Guide ...
Страница 182: ...CIFS Command 144 DD400 Series Restorer User Guide ...
Страница 194: ...Procedure Replace a Replica 156 DD400 Series Restorer User Guide ...
Страница 210: ...Send Log messages to Another System 172 DD400 Series Restorer User Guide ...
Страница 228: ...Operations for Trained Service Personnel 190 DD400 Series Restorer User Guide ...
Страница 300: ...262 DD400 Series Restorer User Guide ...