Disclaimer:

 A claim under warranty solely exists when the from DAS Energy and Innotec prescribed adhesives 

are used and processed in accordance with the bonding instructions by Innotec. In addition, please note that the 
mounting via bonding inevitably leads to irreversible or difficulty repairable modifications of the substrate the 
modules are bonded on. DAS Energy is not liable for possible damages to the substrate due to the assembly or 
rather disassembly of the modules.

Bonding on plastic 

roof sheetings

Bonding on bitumen 

roofing membranes

Bonding on metal 

sub-constructions

IV. MODULE INSTALLATION

During installation, the installer must unconditionally follow the general rules for safety at 
work, the rules for electrical installation and devices, the local applicable construction rules 
and all other regional and national rules and regulations.

DAS Energy modules are typically mounted via bonding, either directly on a substrate or, if necessary, on a 
supporting sub-construction. The bonding method depends on the material and the properties of the substrate. 
Alternatively, the modules can also be bolted, e.g. to a metal sub-construction, by means of holes or eyelets in 
the module edge zones.

The PV modules can be mounted in landscape or por-
trait orientation. In any case, the adhesive beads must 
be applied in water flow direction. Identify and, if possi-
ble, leave out recurring sources of dirt and avoid shad-
ing sources. Install the cable tray at a distance of at least 
10 mm from the roof and, where possible, in water flow 
direction, so that rainwater can drain unhindered (refer 
to V. Electrical installation: Cable trays).

The DAS Energy PV modules are intended to be bonded 
directly onto a roofing membrane or roof sheeting, or, 
alternatively, onto a supporting sub-construction. For 
this purpose, please follow the bonding instructions by 

Innotec (refer to Bonding instructions, Art. no. 199131-2). 
Use only the from DAS Energy and Innotec prescribed 
adhesives “

Versabond Photovoltaic

” or “

Adheseal Pho-

tovoltaic

” as well as the cleaning agent “

Multisol  Pro ject

” 

with the cleaning cloth “

Multi Wipes

”, all from Innotec. 

Note the processing temperature of the adhesive and 
the temperature of the substrate. Make sure the sub-
strate as well as the backside of the PV module is dry 
and free of dust and grease before gluing (e.g. rust, old 
paint, etc. must be removed upfront). With the follow-
ing QR codes training videos for the appropriate instal-
lation of the DAS Energy PV modules via bonding can 
be found.

MOUNTING VIA BONDING

In any case, do not modify the module backside!
Plug & socket must not get into contact with the cleaning agent Multisol Project!

7

Module installation

Содержание 6x1M RJB

Страница 1: ...INSTALLATION MANUAL DAS Energy Modules...

Страница 2: ...ON AND MAINTENANCE VISUAL INSPECTION CLEANING MODULE REPLACEMENT DISMANTLING VII DISPOSAL VIII POTENTIAL SOURCES OF FAULTS IX TECHNICAL DETAILS PRODUCT MARKING PRODUCT LABEL SAFETY APPLICATION CLASS F...

Страница 3: ...lls and the position of the junction box PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS This installation manual is applicable to the PV module types as listed below 6x1M RJB 6x1M FJB 6x2M RJB 6x2M...

Страница 4: ...ty from the employer s liability insur ance associations Assembly installation and initial operation of the modules requires expert knowledge and must only be car ried out by qualified and authorized...

Страница 5: ...and dry room until installation The packaging is not weath er proof Do NOT attempt to repair a damaged module Do NOT concentrate sunlight e g mirrors or lenses or other sources of artificial light on...

Страница 6: ...ways be pro tected from pollution e g dust humidity foreign particles etc prior to installa tion the modules are supplied with protective dust caps on the PV4 S connectors Do not leave unconnected unp...

Страница 7: ...um per missible loads The modules should be installed in such a way that there is no shading throughout the year It must be en sured that there is no obstacle or other roof structure which can cause p...

Страница 8: ...ig 2 show a typical module layout In order to compensate for the thermal linear expansion of the modules and the substrate an inter module distance of at least 30 mm must be maintained A larger dis ta...

Страница 9: ...in landscape or por trait orientation In any case the adhesive beads must be applied in water flow direction Identify and if possi ble leave out recurring sources of dirt and avoid shad ing sources In...

Страница 10: ...at Standard Test Conditions 1 000 W m 25 2 C AM 1 5 Under normal conditions a photo voltaic module is likely to experience conditions that produce more current and or voltage than reported at STC Sta...

Страница 11: ...bending radius R 5 x Cable diameter must be maintained see Fig 5 Despite the cables are sun light resist ant and waterproof protection class IP 68 where possible place the cables in cable ducts in or...

Страница 12: ...cal connection Plugs and junction boxes must not get into contact with the Multisol Project cleaning agent Do not attempt to make an electrical connection with wet soiled or otherwise faulty connector...

Страница 13: ...y must always be consulted in advance Only after verification and confirmation from DAS Energy the replacement of the damaged MC4 Evo 2 connectors is permitted In case the MC4 Evo2 connector should be...

Страница 14: ...locked and engaged When the connectors are correctly connected the latches of the positive connector should be flush with the latches of the negative connector see Fig 8 Please use the corresponding...

Страница 15: ...The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded The DAS Energy modules do not suffer from PID due to the...

Страница 16: ...eplacement may be necessary The dismantling of DAS Energy modules is possible at both screw fastened mounting and bonded mounting Avoid cleaning the modules on hot sunny days in the middle of the day...

Страница 17: ...cutting wire between the module and the substrate lengthwise through the adhesive beads as shown in Fig 11 Take care here not the damage adjoining modules After wards the module can be detached from t...

Страница 18: ...ndered Shading orientation Avoid shading sources cable trays Remove concentrated dirt accumulations from the module surface Linear expansion Distance of 30 mm plastic and bitumen roof sheeting between...

Страница 19: ...mechanical mounting instructions refer to IV Module installation Please find below the datasheet of the module types to which this manual is applicable The module types are subject to changes without...

Страница 20: ...eet EXTREME WEATHER CONDITIONS Even in heat sandstorms and dusty conditions the module provides stable and durable performance COMPOSITE SUPERLIGHT MODULE 11x6 TECHNICAL DATA Solar cells 5BB monocryst...

Страница 21: ...oc 7 91 Vmp 7 x 3 M 105 Wp 14 38 Voc 11 87 Vmp 7 x 4 M 140 Wp 19 17 Voc 15 82 Vmp 7 x 5 M 175 Wp 23 96 Voc 19 78 Vmp 7 x 6 M 210 Wp 28 76 Voc 23 73 Vmp 1113 mm 6 6 x 1 M 30 Wp 4 11 Voc 3 39 Vmp 6 x 2...

Страница 22: ...d ausschlie lich informativ und ersetzen keine eigene Haftungspr fung 6 FREIGABETABELLE Gestestete und freigegebene Untergr nde Release Type date Clean with Kunststoff EPDM Firestone RubberGard 02 201...

Страница 23: ...21 Declaration of Conformity...

Страница 24: ...ww das energy com download datasheets Branch Austria 05 2023 EN DAS Energy Ltd The General Warranty and Terms and Conditions of DAS Energy Ltd apply Subject to typographical and printing errors as wel...

Отзывы: