COMPOSITE SUPERLIGHT MODULE 

11 x 6

COMPOSITE 

SUPER LIGHT

MODUL

AVAILABLE SIZES

ULTRA-LIGHTWEIGHT

EASY INSTALLATION

PATENTED DESIGN

FLEXIBLE | BENDABLE

HIGH EFFICIENCY

HIGHER ENERGY YIELD

EXTREMELY 

WEATHER RESISTANT

COSTUMIZED  

SOLUTIONS

HIGH RELIABILITY

2035 mm

12

12 x 1 M

60 Wp

8.22 Voc

6.78 Vmp

12 x 2 M

120 Wp

16.43 Voc

13.56 Vmp

1917 mm

11

11 x 1 M

55Wp

7.53 Voc

6.22 Vmp

11 x 2 M

110Wp

15.06 Voc

12.43 Vmp

11 x 3 M

165Wp

22.60 Voc

18.65 Vmp

11 x 4 M

220 Wp

30.13 Voc

24.86 Vmp

11 x 5 M

280 Wp

37.66 Voc

31.08 Vmp

11 x 6 M

330 Wp

45.19 Voc

37.29 Vmp

1756 mm

10

10 x 1 M

50 Wp

6.85 Voc

5.65 Vmp

10 x 2 M

100 Wp

13.69 Voc

11.30 Vmp

10 x 3 M

150 Wp

20.54 Voc

16.95 Vmp

10 x 4 M

200 Wp

27.39 Voc

22.60 Vmp

10 x 5 M

250 Wp

34.23 Voc

28.25 Vmp

10 x 6 M

300 Wp

41.08 Voc

33.90 Vmp

1595 mm

9

9 x 1 M

45 Wp

6.16 Voc

5.09 Vmp

9 x 2 M

90 Wp

12.32 Voc

10.17 Vmp

9 x 3 M

135 Wp

18.49 Voc

15.26 Vmp

9 x 4 M

180 Wp

24.65 Voc

20.34 Vmp

9 x 5 M

225 Wp

30.81 Voc

25.43 Vmp

9 x 6 M

270 Wp

36.97 Voc

30.51 Vmp

1434 mm

8

8 x 1 M

40 Wp

5.48 Voc

4.52 Vmp

8 x 2 M

80 Wp

10.96 Voc
9.04 Vmp

8 x 3 M

120 Wp

16.43 Voc

13.56 Vmp

8 x 4 M

160 Wp

21.91 Voc

18.08 Vmp

8 x 5 M

200 Wp

27.39 Voc

22.60 Vmp

8 x 6 M

240 Wp

32.87 Voc
27.12 Vmp

1274 mm

7

7 x 1 M

35 Wp

4.79 Voc

3.96 Vmp

7 x 2 M

70 Wp

9.59 Voc
7.91 Vmp

7 x 3 M

105 Wp

14.38 Voc

11.87 Vmp

7 x 4 M

140 Wp

19.17 Voc

15.82 Vmp

7 x 5 M

175 Wp

23.96 Voc

19.78 Vmp

7 x 6 M

210 Wp

28.76 Voc

23.73 Vmp

1113 mm

6

6 x 1 M

30 Wp

4.11 Voc

3.39 Vmp

6 x 2 M

60 Wp

8.22 Voc

6.78 Vmp

6 x 3 M

90 Wp

12.32 Voc

10.17 Vmp

6 x 4 M

120 Wp

16.43 Voc

13.56 Vmp

6 x 5 M

150 Wp

20.54 Voc

16.95 Vmp

6 x 6 M

180 Wp

24.65 Voc

20.34 Vmp

1

2

3

4

5

6

227 mm

377 mm

548 mm

699 mm

870 mm

1020 mm

LENGTH F

JB & R

JB

WIDTH

STÄRKE 2 MM ± 0.3

Building-integrated and 

building-applied PV

(rooftop, facade),

special applications

HIGH RELIABILITY

POWER RANGE

20 - 330 Wp

WARRANTY

APPLICATIONS

conform to:

IEC 61730  |  IEC 61215

IEC 62804-1  

Potential-induced degradation

IEC 61701 Salt mist corrosion

IEC 62716 Ammonia corrosion

EN 13501-5 B 

ROOF

 (t1)  

“Flying sparks test”

10-year product warranty

40-year linear performance

warranty for building-inte-

gratedand building-applied 

installations

* all electrical data at STC 

(1.000 W/m

2, 

25 +/-2 

°C

, AM 1.5 

according to IEC 60904-3)

Tolerances*
≥ 250 Wp: 
< 250 Wp:
Isc: 
Voc: 

- 0 / + 10 W

- 5 / + 5 W

+/- 10 %  
+/- 10 %

Tel / +43 2622 35035 

E-Mail / [email protected]

Web / www.das-energy.com

Ferdinand Graf von Zeppelin-Straße 18

2700 Wiener Neustadt, Austria

www.das-energy.com

download factsheets

© 05 / 2023 / EN / 

D

AS Energy L

td.

 Niederlassung Österreich 

| The gener

al terms and conditions of 

D

AS Energy L

td.

 Niederlassung Österreich 

 apply

. T

ypogr

aphical and printing errors as w

ell as technical changes reserv

ed.

SCIENTIFIC PARTNERS AND ASSOCIATIONS

Содержание 6x1M RJB

Страница 1: ...INSTALLATION MANUAL DAS Energy Modules...

Страница 2: ...ON AND MAINTENANCE VISUAL INSPECTION CLEANING MODULE REPLACEMENT DISMANTLING VII DISPOSAL VIII POTENTIAL SOURCES OF FAULTS IX TECHNICAL DETAILS PRODUCT MARKING PRODUCT LABEL SAFETY APPLICATION CLASS F...

Страница 3: ...lls and the position of the junction box PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS This installation manual is applicable to the PV module types as listed below 6x1M RJB 6x1M FJB 6x2M RJB 6x2M...

Страница 4: ...ty from the employer s liability insur ance associations Assembly installation and initial operation of the modules requires expert knowledge and must only be car ried out by qualified and authorized...

Страница 5: ...and dry room until installation The packaging is not weath er proof Do NOT attempt to repair a damaged module Do NOT concentrate sunlight e g mirrors or lenses or other sources of artificial light on...

Страница 6: ...ways be pro tected from pollution e g dust humidity foreign particles etc prior to installa tion the modules are supplied with protective dust caps on the PV4 S connectors Do not leave unconnected unp...

Страница 7: ...um per missible loads The modules should be installed in such a way that there is no shading throughout the year It must be en sured that there is no obstacle or other roof structure which can cause p...

Страница 8: ...ig 2 show a typical module layout In order to compensate for the thermal linear expansion of the modules and the substrate an inter module distance of at least 30 mm must be maintained A larger dis ta...

Страница 9: ...in landscape or por trait orientation In any case the adhesive beads must be applied in water flow direction Identify and if possi ble leave out recurring sources of dirt and avoid shad ing sources In...

Страница 10: ...at Standard Test Conditions 1 000 W m 25 2 C AM 1 5 Under normal conditions a photo voltaic module is likely to experience conditions that produce more current and or voltage than reported at STC Sta...

Страница 11: ...bending radius R 5 x Cable diameter must be maintained see Fig 5 Despite the cables are sun light resist ant and waterproof protection class IP 68 where possible place the cables in cable ducts in or...

Страница 12: ...cal connection Plugs and junction boxes must not get into contact with the Multisol Project cleaning agent Do not attempt to make an electrical connection with wet soiled or otherwise faulty connector...

Страница 13: ...y must always be consulted in advance Only after verification and confirmation from DAS Energy the replacement of the damaged MC4 Evo 2 connectors is permitted In case the MC4 Evo2 connector should be...

Страница 14: ...locked and engaged When the connectors are correctly connected the latches of the positive connector should be flush with the latches of the negative connector see Fig 8 Please use the corresponding...

Страница 15: ...The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded The DAS Energy modules do not suffer from PID due to the...

Страница 16: ...eplacement may be necessary The dismantling of DAS Energy modules is possible at both screw fastened mounting and bonded mounting Avoid cleaning the modules on hot sunny days in the middle of the day...

Страница 17: ...cutting wire between the module and the substrate lengthwise through the adhesive beads as shown in Fig 11 Take care here not the damage adjoining modules After wards the module can be detached from t...

Страница 18: ...ndered Shading orientation Avoid shading sources cable trays Remove concentrated dirt accumulations from the module surface Linear expansion Distance of 30 mm plastic and bitumen roof sheeting between...

Страница 19: ...mechanical mounting instructions refer to IV Module installation Please find below the datasheet of the module types to which this manual is applicable The module types are subject to changes without...

Страница 20: ...eet EXTREME WEATHER CONDITIONS Even in heat sandstorms and dusty conditions the module provides stable and durable performance COMPOSITE SUPERLIGHT MODULE 11x6 TECHNICAL DATA Solar cells 5BB monocryst...

Страница 21: ...oc 7 91 Vmp 7 x 3 M 105 Wp 14 38 Voc 11 87 Vmp 7 x 4 M 140 Wp 19 17 Voc 15 82 Vmp 7 x 5 M 175 Wp 23 96 Voc 19 78 Vmp 7 x 6 M 210 Wp 28 76 Voc 23 73 Vmp 1113 mm 6 6 x 1 M 30 Wp 4 11 Voc 3 39 Vmp 6 x 2...

Страница 22: ...d ausschlie lich informativ und ersetzen keine eigene Haftungspr fung 6 FREIGABETABELLE Gestestete und freigegebene Untergr nde Release Type date Clean with Kunststoff EPDM Firestone RubberGard 02 201...

Страница 23: ...21 Declaration of Conformity...

Страница 24: ...ww das energy com download datasheets Branch Austria 05 2023 EN DAS Energy Ltd The General Warranty and Terms and Conditions of DAS Energy Ltd apply Subject to typographical and printing errors as wel...

Отзывы: