DAS Energy 6x1M RJB Скачать руководство пользователя страница 5

HANDLING OF THE MODULES

•  Do NOT attempt to transport, handle, or install the 

modules by yourself without a second person. Trans-
port,  handling, and installation of the modules should 
be done by at least two persons.

 

Do NOT bend or snap the modules (remark: the mod-
ules are flexible but should only be bent when finally 
mounted on a round mounting base).

 

Do NOT place the modules on the corners nor on the 
edges!

 

Do NOT apply forces while laying the modules down 
(do not throw the module).

 

Do NOT apply focused pressure on the modules in or-
der to avoid punctures, cuts, or tears.

 

Do NOT step on the modules (depending on the under-
ground the modules can eventually be damaged).

 

Do NOT lean the modules on sharp or spiky objects.

 

Do NOT drop heavy or sharp objects onto the modules.

 

Do NOT use the junction box or the connection cable as 
a help for handling.

 

Do NOT cut or pierce the module as this may cause live 
components to be exposed and/or damage the module. 

Do NOT bend or apply excessive force to the cables.

 

Do NOT stack modules (the junction box shall not be in 
contact with the front surface, because the sharp edg-
es of the junction box may damage the front surface).

 

Do NOT scratch or hit the module frontside or the 
backsheet.

 

Do NOT apply paint, varnish, or protective coatings to 
the modules.

 

Do NOT dismantle or remove any part or label at-
tached by the manufacturer.

 

Do NOT open the original packaging during transpor-
tation and storing until installation. At the same time, 
please protect the packaging from damage and store 
the packages securely in a ventilated, cool, and dry 
room until installation. The packaging is not weath-
er-proof.

 

Do NOT attempt to repair a damaged module.

 

Do NOT concentrate sunlight (e.g. mirrors or lenses) or 
other sources of artificial light on the modules.

 

Do NOT use photovoltaic modules in the presence of 
inflammable or explosive substances.

Maximum bending:

 DAS Energy modules are flexible, but 

they cannot be rolled-up or folded. Poly- and monocrys-
talline modules may be bent up to a maximum radius of 
2,000 mm (only the long side of the module should be 
bent). Smaller radii are not permitted. Excessive bending 
must be avoided when handling the mod ules. The maxi-
mum bending mentioned should be understood only for 
one-time bending to permanently mount the modules on 
round surfaces. The modules are not designed to with-
stand such maximum bending radius for applications 
where bending occurs repeatedly or periodically. The 

bending process must be done uniformly as punctual 
bending may cause permanent damage to the cells. The 
modules should not be held only on the short ends or 
corners as this may cause excessive bending under their 
own weight.

Not following those points may cause single PV cells to 
break inside the module or injure the protective layer of 
the composite! Mishandling of the module may lead to a 
decrease of the performance or aspect of the mod ules, 
for which DAS Energy shall not be held liable.

II.  SAFETY INSTRUCTIONS

The correct handling of DAS Energy modules is essential for the durability of the product. Therefore, the most im-
portant notes on proper handling of the modules are listed below.

Make sure to read through and observe the following safety instructions, in order to avoid personal 
injuries and damages on the modules under all circumstances.

3

Safety instructions

Содержание 6x1M RJB

Страница 1: ...INSTALLATION MANUAL DAS Energy Modules...

Страница 2: ...ON AND MAINTENANCE VISUAL INSPECTION CLEANING MODULE REPLACEMENT DISMANTLING VII DISPOSAL VIII POTENTIAL SOURCES OF FAULTS IX TECHNICAL DETAILS PRODUCT MARKING PRODUCT LABEL SAFETY APPLICATION CLASS F...

Страница 3: ...lls and the position of the junction box PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS This installation manual is applicable to the PV module types as listed below 6x1M RJB 6x1M FJB 6x2M RJB 6x2M...

Страница 4: ...ty from the employer s liability insur ance associations Assembly installation and initial operation of the modules requires expert knowledge and must only be car ried out by qualified and authorized...

Страница 5: ...and dry room until installation The packaging is not weath er proof Do NOT attempt to repair a damaged module Do NOT concentrate sunlight e g mirrors or lenses or other sources of artificial light on...

Страница 6: ...ways be pro tected from pollution e g dust humidity foreign particles etc prior to installa tion the modules are supplied with protective dust caps on the PV4 S connectors Do not leave unconnected unp...

Страница 7: ...um per missible loads The modules should be installed in such a way that there is no shading throughout the year It must be en sured that there is no obstacle or other roof structure which can cause p...

Страница 8: ...ig 2 show a typical module layout In order to compensate for the thermal linear expansion of the modules and the substrate an inter module distance of at least 30 mm must be maintained A larger dis ta...

Страница 9: ...in landscape or por trait orientation In any case the adhesive beads must be applied in water flow direction Identify and if possi ble leave out recurring sources of dirt and avoid shad ing sources In...

Страница 10: ...at Standard Test Conditions 1 000 W m 25 2 C AM 1 5 Under normal conditions a photo voltaic module is likely to experience conditions that produce more current and or voltage than reported at STC Sta...

Страница 11: ...bending radius R 5 x Cable diameter must be maintained see Fig 5 Despite the cables are sun light resist ant and waterproof protection class IP 68 where possible place the cables in cable ducts in or...

Страница 12: ...cal connection Plugs and junction boxes must not get into contact with the Multisol Project cleaning agent Do not attempt to make an electrical connection with wet soiled or otherwise faulty connector...

Страница 13: ...y must always be consulted in advance Only after verification and confirmation from DAS Energy the replacement of the damaged MC4 Evo 2 connectors is permitted In case the MC4 Evo2 connector should be...

Страница 14: ...locked and engaged When the connectors are correctly connected the latches of the positive connector should be flush with the latches of the negative connector see Fig 8 Please use the corresponding...

Страница 15: ...The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded The DAS Energy modules do not suffer from PID due to the...

Страница 16: ...eplacement may be necessary The dismantling of DAS Energy modules is possible at both screw fastened mounting and bonded mounting Avoid cleaning the modules on hot sunny days in the middle of the day...

Страница 17: ...cutting wire between the module and the substrate lengthwise through the adhesive beads as shown in Fig 11 Take care here not the damage adjoining modules After wards the module can be detached from t...

Страница 18: ...ndered Shading orientation Avoid shading sources cable trays Remove concentrated dirt accumulations from the module surface Linear expansion Distance of 30 mm plastic and bitumen roof sheeting between...

Страница 19: ...mechanical mounting instructions refer to IV Module installation Please find below the datasheet of the module types to which this manual is applicable The module types are subject to changes without...

Страница 20: ...eet EXTREME WEATHER CONDITIONS Even in heat sandstorms and dusty conditions the module provides stable and durable performance COMPOSITE SUPERLIGHT MODULE 11x6 TECHNICAL DATA Solar cells 5BB monocryst...

Страница 21: ...oc 7 91 Vmp 7 x 3 M 105 Wp 14 38 Voc 11 87 Vmp 7 x 4 M 140 Wp 19 17 Voc 15 82 Vmp 7 x 5 M 175 Wp 23 96 Voc 19 78 Vmp 7 x 6 M 210 Wp 28 76 Voc 23 73 Vmp 1113 mm 6 6 x 1 M 30 Wp 4 11 Voc 3 39 Vmp 6 x 2...

Страница 22: ...d ausschlie lich informativ und ersetzen keine eigene Haftungspr fung 6 FREIGABETABELLE Gestestete und freigegebene Untergr nde Release Type date Clean with Kunststoff EPDM Firestone RubberGard 02 201...

Страница 23: ...21 Declaration of Conformity...

Страница 24: ...ww das energy com download datasheets Branch Austria 05 2023 EN DAS Energy Ltd The General Warranty and Terms and Conditions of DAS Energy Ltd apply Subject to typographical and printing errors as wel...