DAS Energy 6x1M RJB Скачать руководство пользователя страница 4

DAS Energy cannot control the use of this safety, in-
stallation, and instruction manual or the conditions 
and procedures for installing, operating, using, and 
maintaining the modules. Therefore, DAS Energy as-
sumes no responsibility and expressly disclaims lia-
bility for loss, damage, injuries, casualties, or expense 
arising out of or in any connection with installation, op-
eration, use or maintenance of the modules. Any mod-
ifications or any use of DAS Energy products contrary 
to their specifications and not expressly authorized by 
DAS Energy will result in a loss of any liability claims. 

The information in the manual is based on the knowl-
edge and experience of DAS Energy and is considered 
to be accurate and reliable. However, information, 
product  specifications  and  sugges tions  have  neither 
the explicit nor implicit nature of a guarantee. DAS 
Energy reserves the right to modify its products, the 
technical  specifications  and  installation  instructions 
without notice.

IMPORTANT NOTES

DISCLAIMER

•  Please make sure that you have read and under-

stood all the safety information in this installation 
guide be fore installing and operating the modules. 

•  Please observe all local, regional, national, and 

international legal provisions, guidelines, stan-
dards, and regu lations, as well as the guidelines 
on work safety from the employer’s liability insur-
ance associations.

 

Assembly, installation, and initial operation of the 
modules requires expert knowledge and must 
only  be  car ried  out  by  qualified  and  authorized 
professionals.

 

The modules must be checked for mechanical in-
tegrity before installation. Damaged modules must 
not be installed.

 

DAS Energy PV modules meet the requirements ac-
cording to IEC 6215 and IEC 61730 (application class 
A, protection class II). Modules of this application 
class can be used in systems operated with more 
than 50 V DC in generally accessible environments.  

The modules almost produce full voltage also un-
der bad lighting conditions, even when they are 
not connect ed to an electric current, i.e. caution is 
always advised during installation with regard to 
electrical faults e.g. short circuits.

 

The real output power produced by the modules 
can be above the specified nominal power. The giv-
en nomi nal power is determined according to indus-
try standard at 1,000 W/m² radiation intensity and 
25 °C solar cell temperature. In practical operation 
the current intensity, voltage and resulting power 
produced by the module can increase as a result of 
colder ambient temperatures or the reflection from 
snow, water, or other reflec tive surfaces.

 

Avoid focusing light and directing it onto the module.

 

Only use devices, connectors and cables which are 
suitable for use with photovoltaic systems.

 

Please observe all safety measures and instruc-
tions for other components used.

2

General information

Содержание 6x1M RJB

Страница 1: ...INSTALLATION MANUAL DAS Energy Modules...

Страница 2: ...ON AND MAINTENANCE VISUAL INSPECTION CLEANING MODULE REPLACEMENT DISMANTLING VII DISPOSAL VIII POTENTIAL SOURCES OF FAULTS IX TECHNICAL DETAILS PRODUCT MARKING PRODUCT LABEL SAFETY APPLICATION CLASS F...

Страница 3: ...lls and the position of the junction box PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS This installation manual is applicable to the PV module types as listed below 6x1M RJB 6x1M FJB 6x2M RJB 6x2M...

Страница 4: ...ty from the employer s liability insur ance associations Assembly installation and initial operation of the modules requires expert knowledge and must only be car ried out by qualified and authorized...

Страница 5: ...and dry room until installation The packaging is not weath er proof Do NOT attempt to repair a damaged module Do NOT concentrate sunlight e g mirrors or lenses or other sources of artificial light on...

Страница 6: ...ways be pro tected from pollution e g dust humidity foreign particles etc prior to installa tion the modules are supplied with protective dust caps on the PV4 S connectors Do not leave unconnected unp...

Страница 7: ...um per missible loads The modules should be installed in such a way that there is no shading throughout the year It must be en sured that there is no obstacle or other roof structure which can cause p...

Страница 8: ...ig 2 show a typical module layout In order to compensate for the thermal linear expansion of the modules and the substrate an inter module distance of at least 30 mm must be maintained A larger dis ta...

Страница 9: ...in landscape or por trait orientation In any case the adhesive beads must be applied in water flow direction Identify and if possi ble leave out recurring sources of dirt and avoid shad ing sources In...

Страница 10: ...at Standard Test Conditions 1 000 W m 25 2 C AM 1 5 Under normal conditions a photo voltaic module is likely to experience conditions that produce more current and or voltage than reported at STC Sta...

Страница 11: ...bending radius R 5 x Cable diameter must be maintained see Fig 5 Despite the cables are sun light resist ant and waterproof protection class IP 68 where possible place the cables in cable ducts in or...

Страница 12: ...cal connection Plugs and junction boxes must not get into contact with the Multisol Project cleaning agent Do not attempt to make an electrical connection with wet soiled or otherwise faulty connector...

Страница 13: ...y must always be consulted in advance Only after verification and confirmation from DAS Energy the replacement of the damaged MC4 Evo 2 connectors is permitted In case the MC4 Evo2 connector should be...

Страница 14: ...locked and engaged When the connectors are correctly connected the latches of the positive connector should be flush with the latches of the negative connector see Fig 8 Please use the corresponding...

Страница 15: ...The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded The DAS Energy modules do not suffer from PID due to the...

Страница 16: ...eplacement may be necessary The dismantling of DAS Energy modules is possible at both screw fastened mounting and bonded mounting Avoid cleaning the modules on hot sunny days in the middle of the day...

Страница 17: ...cutting wire between the module and the substrate lengthwise through the adhesive beads as shown in Fig 11 Take care here not the damage adjoining modules After wards the module can be detached from t...

Страница 18: ...ndered Shading orientation Avoid shading sources cable trays Remove concentrated dirt accumulations from the module surface Linear expansion Distance of 30 mm plastic and bitumen roof sheeting between...

Страница 19: ...mechanical mounting instructions refer to IV Module installation Please find below the datasheet of the module types to which this manual is applicable The module types are subject to changes without...

Страница 20: ...eet EXTREME WEATHER CONDITIONS Even in heat sandstorms and dusty conditions the module provides stable and durable performance COMPOSITE SUPERLIGHT MODULE 11x6 TECHNICAL DATA Solar cells 5BB monocryst...

Страница 21: ...oc 7 91 Vmp 7 x 3 M 105 Wp 14 38 Voc 11 87 Vmp 7 x 4 M 140 Wp 19 17 Voc 15 82 Vmp 7 x 5 M 175 Wp 23 96 Voc 19 78 Vmp 7 x 6 M 210 Wp 28 76 Voc 23 73 Vmp 1113 mm 6 6 x 1 M 30 Wp 4 11 Voc 3 39 Vmp 6 x 2...

Страница 22: ...d ausschlie lich informativ und ersetzen keine eigene Haftungspr fung 6 FREIGABETABELLE Gestestete und freigegebene Untergr nde Release Type date Clean with Kunststoff EPDM Firestone RubberGard 02 201...

Страница 23: ...21 Declaration of Conformity...

Страница 24: ...ww das energy com download datasheets Branch Austria 05 2023 EN DAS Energy Ltd The General Warranty and Terms and Conditions of DAS Energy Ltd apply Subject to typographical and printing errors as wel...

Отзывы: