Thank you for purchasing a DAS Energy product. Our 
photovoltaic modules are built using our patented 
innova tive technology and top-quality materials.

The following guidelines have been provided to avoid 
mistakes when installing the modules. Only trained 
spe cialists should conduct the static calculations, 
planning and subsequent installation of solar mod-
ules, including their permitted substructure. They 
must be familiar with the applicable laws and ordi-

nances of the respective country and with the special 
regulations for photovoltaic systems. Exceeding or 
undercutting of the permissible loads, such as wind 
and snow loads will render the warranty void. In ad-
dition to the following instructions, we recommend 
to use, follow and respect IEC 62548 (“Photovoltaic 
arrays – design requirements”).

I.  GENERAL INFORMATION

The DAS Energy PV modules are designated according to the respective number of cells and the position of 
the junction box:

PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS

This installation manual is applicable to the PV module types as listed below:

6x1M RJB

6x1M FJB

6x2M RJB

6x2M FJB

6x3M RJB

6x3M FJB

6x4M RJB

6x4M FJB 6x5M RJB 6x5M FJB 6x6M RJB 6x6M FJB

7x1M RJB

7x1M FJB

7x2M RJB

7x2M FJB

7x3M RJB

7x3M FJB

7x4M RJB

7x4M FJB

7x5M RJB

7x5M FJB

7x6M RJB

7x6M FJB

8x1M RJB

8x1M FJB

8x2M RJB 8x2M FJB 8x3M RJB

8x3M FJB

8x4M RJB

8x4M FJB 8x5M RJB 8x5M FJB 8x6M RJB 8x6M FJB

9x1M RJB

9x1M FJB

9x2M RJB

9x2M FJB

9x3M RJB

9x3M FJB

9x4M RJB

9x4M FJB 9x5M RJB 9x5M FJB 9x6M RJB 9x6M FJB

10x1M RJB 10x1M FJB 10x2M RJB 10x2M FJB 10x3M RJB 10x3M FJB 10x4M RJB 10x4M FJB 10x5M RJB 10x5M FJB 10x6M RJB 10x6M FJB

11x1M RJB

11x1M FJB

11x2M RJB 11x2M FJB 11x3M RJB 11x3M FJB 11x4M RJB 11x4M FJB 11x5M RJB 11x5M FJB 11x6M RJB 11x6M FJB

12x1M RJB 12x1M FJB 12x2M RJB 12x2M FJB

DAS ENERGY PV MODULE

...  x    ...  M    ...

 

 (e.g. 11x6M FJB)

Number of cells longitudinally: 6 … 12

Number of cells transversally: 1 … 6

M for monocrystalline

Mounting position of the junction box: 
Front: FJB
Rear: RJB

1

General information

Содержание 6x1M RJB

Страница 1: ...INSTALLATION MANUAL DAS Energy Modules...

Страница 2: ...ON AND MAINTENANCE VISUAL INSPECTION CLEANING MODULE REPLACEMENT DISMANTLING VII DISPOSAL VIII POTENTIAL SOURCES OF FAULTS IX TECHNICAL DETAILS PRODUCT MARKING PRODUCT LABEL SAFETY APPLICATION CLASS F...

Страница 3: ...lls and the position of the junction box PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS This installation manual is applicable to the PV module types as listed below 6x1M RJB 6x1M FJB 6x2M RJB 6x2M...

Страница 4: ...ty from the employer s liability insur ance associations Assembly installation and initial operation of the modules requires expert knowledge and must only be car ried out by qualified and authorized...

Страница 5: ...and dry room until installation The packaging is not weath er proof Do NOT attempt to repair a damaged module Do NOT concentrate sunlight e g mirrors or lenses or other sources of artificial light on...

Страница 6: ...ways be pro tected from pollution e g dust humidity foreign particles etc prior to installa tion the modules are supplied with protective dust caps on the PV4 S connectors Do not leave unconnected unp...

Страница 7: ...um per missible loads The modules should be installed in such a way that there is no shading throughout the year It must be en sured that there is no obstacle or other roof structure which can cause p...

Страница 8: ...ig 2 show a typical module layout In order to compensate for the thermal linear expansion of the modules and the substrate an inter module distance of at least 30 mm must be maintained A larger dis ta...

Страница 9: ...in landscape or por trait orientation In any case the adhesive beads must be applied in water flow direction Identify and if possi ble leave out recurring sources of dirt and avoid shad ing sources In...

Страница 10: ...at Standard Test Conditions 1 000 W m 25 2 C AM 1 5 Under normal conditions a photo voltaic module is likely to experience conditions that produce more current and or voltage than reported at STC Sta...

Страница 11: ...bending radius R 5 x Cable diameter must be maintained see Fig 5 Despite the cables are sun light resist ant and waterproof protection class IP 68 where possible place the cables in cable ducts in or...

Страница 12: ...cal connection Plugs and junction boxes must not get into contact with the Multisol Project cleaning agent Do not attempt to make an electrical connection with wet soiled or otherwise faulty connector...

Страница 13: ...y must always be consulted in advance Only after verification and confirmation from DAS Energy the replacement of the damaged MC4 Evo 2 connectors is permitted In case the MC4 Evo2 connector should be...

Страница 14: ...locked and engaged When the connectors are correctly connected the latches of the positive connector should be flush with the latches of the negative connector see Fig 8 Please use the corresponding...

Страница 15: ...The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded The DAS Energy modules do not suffer from PID due to the...

Страница 16: ...eplacement may be necessary The dismantling of DAS Energy modules is possible at both screw fastened mounting and bonded mounting Avoid cleaning the modules on hot sunny days in the middle of the day...

Страница 17: ...cutting wire between the module and the substrate lengthwise through the adhesive beads as shown in Fig 11 Take care here not the damage adjoining modules After wards the module can be detached from t...

Страница 18: ...ndered Shading orientation Avoid shading sources cable trays Remove concentrated dirt accumulations from the module surface Linear expansion Distance of 30 mm plastic and bitumen roof sheeting between...

Страница 19: ...mechanical mounting instructions refer to IV Module installation Please find below the datasheet of the module types to which this manual is applicable The module types are subject to changes without...

Страница 20: ...eet EXTREME WEATHER CONDITIONS Even in heat sandstorms and dusty conditions the module provides stable and durable performance COMPOSITE SUPERLIGHT MODULE 11x6 TECHNICAL DATA Solar cells 5BB monocryst...

Страница 21: ...oc 7 91 Vmp 7 x 3 M 105 Wp 14 38 Voc 11 87 Vmp 7 x 4 M 140 Wp 19 17 Voc 15 82 Vmp 7 x 5 M 175 Wp 23 96 Voc 19 78 Vmp 7 x 6 M 210 Wp 28 76 Voc 23 73 Vmp 1113 mm 6 6 x 1 M 30 Wp 4 11 Voc 3 39 Vmp 6 x 2...

Страница 22: ...d ausschlie lich informativ und ersetzen keine eigene Haftungspr fung 6 FREIGABETABELLE Gestestete und freigegebene Untergr nde Release Type date Clean with Kunststoff EPDM Firestone RubberGard 02 201...

Страница 23: ...21 Declaration of Conformity...

Страница 24: ...ww das energy com download datasheets Branch Austria 05 2023 EN DAS Energy Ltd The General Warranty and Terms and Conditions of DAS Energy Ltd apply Subject to typographical and printing errors as wel...

Отзывы: