83
5.0 UPC Types
5.2.3
Enable/Disable ISBT 128 :
Parameter # 0x54
To enable or disable ISBT 128, scan the appropriate bar code below.
5.2.4
Lengths for Code 128
No length setting is required for Code 128.
*Enable ISBT 128
(0x01)
Disable ISBT 128
(0x00)
5.3 Code 39
5.3.1
Enable/Disable Code 39 :
Parameter # 0x00
To enable or disable Code 39, scan the appropriate bar code below.
5.3.2
Enable/Disable Trioptic Code 39 :
Parameter # 0x0D
Trioptic Code 39 is a variant of Code 39 used in marking computer tape
cartridges. Trioptic Code 39 symbols always contain six characters.
To enable or disable Trioptic Code 39, scan the appropriate bar code
below.
*Enable Code 39
(0x01)
Enable Trioptic Code 39
(0x01)
Disable Code 39
(0x00)
*Disable Trioptic Code 39
(0x00)
NOTE:
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled
simultaneously. If an error beep sounds when enabling Tri-
optic Code 39, disable Code 39 Full ASCII and try again.
5.3.3
Convert Code 39 to Code 32 (Italian
Pharma Code) :
Parameter # 0x56
Code 32 is a variant of Code 39 used by the Italian pharmaceutical in-
dustry. Scan the appropriate bar code below to enable or disable con-
verting Code 39 to Code 32.
Enable Convert Code 39 to Code 32
(0x01)
NOTE:
Code 39 must be enabled in order for this parameter to func-
tion.
5.3.4
Code 32 Prefix :
Parameter # 0xE7
Enable this parameter to add the prefix character “A” to all Code 32 bar
codes.
Convert Code 39 to Code 32 (Italian Pharma Code)
must
be enabled for this parameter to function.
Enable Code 32 Prefix
(0x01)
*Disable Convert Code 39 to Code 32
(0x00)
*Disable Code 32 Prefix
(0x00)
5.3.5
Set Lengths for Code 39 :
Parameter # L1 = 0x12, L2 = 0x13
The length of a code refers to the number of characters (i.e., human read-
able characters), including check digit(s) the code contains. Lengths for
Code 39 may be set for any length, one or two discrete lengths, or lengths
within a specific range. If Code 39 Full ASCII is enabled,
Length With-
in a Range
or
Any Length
are the preferred options.
NOTE:
When setting lengths, single digit numbers must always be
preceded by a leading zero.