background image

 

 

INSTALLATION 

INFORMATION 

INDICATORS 

 

Voltage presence indicator: 

Positioned on the control panel, it consists of a green indicator light which comes on when there is 
electric voltage present. 
 

LIMIT thermostat intervention indicator: 

Positioned on the control panel, it consists of an orange indicator light which comes on when the 
LIMIT thermal safety device has intervened. 
 

Burner lock indicator: 

Positioned on the control panel, it consists of a red indicator which comes on when a burner lock 
has occurred. 
 
 

INSTALLATION 

INFORMATION 

ENGINE ELECTRIC ABSORPTION 

 

To measure the electrical absorption of the appliance motor, proceed as follows: 

  insert the current probe on a phase of the main supply line; 

  set the machine for operation in summer mode, so as to exclude all other devices (burner and 

auxiliaries); 

  read the electric absorption value on the current clump and compare it with the data written on 

the engine plate. 

 
 

MAINTENANCE 
INFORMATION 

MAINTENANCE 

 

 

 

Repairs  or  maintenance  must  be  performed  by  the  Technical  Assistance  Service  or  by 
qualified personnel. 

 

Disconnect the unit from the main power and fuel supply before any maintenance and / 
or inspection work. 

  In order for the machine to properly work and be maintained, we suggest performing the regular 

cleaning and maintenance operations, according to the indications in the following paragraphs. 

  Cleaning  and  maintenance  interventions  must  be  carried  out  in  relation  to  the  appliance  use 

conditions, to the installation site and to the environment treated. 

  Any action to this effect must be carried out safely by qualified personnel and authorized by the 

cold appliance without the power supply. 

  It is recommended that you use personal safety equipment. 

  All  maintenance/cleaning  operations  requiring  the  use  of  ladder  or  of  other  means,  should  be 

performed with appropriate and completely safe systems. 

  It  is  advisable  to  prepare  a  card  to  report  the  interventions  performed  on  the  appliance  (date, 

description, type of intervention, cause, etc.). 

  If you are not going to use the appliance for long periods, place the main switch and the general 

one on "off". If long periods of unusual operation occur, it is advisable to contact the Technical 
Assistance Service or, in any case, professionally trained personnel to resume operation. 

  Regularly check that all the screws used to assembly the machine are properly fixed. 

 

 

For  appliances  close  to  areas  or  under  particularly  difficult  conditions,  maintenance 
intervals should be more frequent and in any case appropriate to the needs. 

 

Pa

ge.

26

 

Содержание Master BF 105

Страница 1: ...P 1 INSTALLATION AND OPERATION SERIES BF INSTALLATION AND OPERATION...

Страница 2: ...RAL INFORMATION COMPLIANCE The hot air generator mod BF complies with Machinery directive 2006 42 EC Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Regulation 201...

Страница 3: ...g 17 Fuel connection 17 Fume exhaust 18 Combustion air 19 Assembly of diesel burner 19 Burner control 20 Wiring 20 Electrical power supply 21 Wiring diagram reference 21 Control panel 22 Fuel tank 22...

Страница 4: ...shall be fitted only with original accessory equipment The Producer is not liable for damages arising from the improper use of the machine or from the use of non original materials or accessories Ref...

Страница 5: ...within the reach of children the packaging materials cardboard staples plastic bags etc as they may be potentially dangerous Do not install the unit near flammable material or in rooms with an aggres...

Страница 6: ...decreasing section and with opposing turbulencing prints Steel flue gas manifold equipped with an inspection door External casing The casing consists of panels in pre painted and or powder coated shee...

Страница 7: ...eration GENERAL INFORMATION IDENTIFICATION The warm air heaters can be identified through The Technical Plate applied on the machine specifying the main technical performance data In the event of dama...

Страница 8: ...nt 3 Diesel filter where present 4 Filler neck where present 5 Diesel burner 6 Electrical panel 7 Fan 8 Fan support 9 Diaphragm 10 Deflector 11 Deflector 12 Deflector 13 Panel 14 Side panel 15 Beam 16...

Страница 9: ...rform an inversion in the combustion chamber are routed to the first exhaust manifold front manifold and are channelled in the exchange elements smoke pipes arrive in the second exhaust manifold rear...

Страница 10: ...e 10 GENERAL INFORMATION DIMENSIONS AND WEIGHT TYPE A B C D NET WEIGHT1 mm mm mm mm mm kg 1 1 020 500 1 600 1 240 120 140 2 1 120 540 1 700 1 320 150 180 3 1 400 760 2 000 1 580 180 315 1 Without burn...

Страница 11: ...800 5 300 8 800 Nominal air thermal gradient K 29 32 31 FAN thermostat calibration C 35 35 35 LIMIT thermostat calibration C 100 100 100 Sound pressure emission 4 dB A 57 60 70 Range of use C 5 40 5...

Страница 12: ...ow 90 6 89 7 89 9 s h 72 3 72 1 72 9 Legend P rated h Nominal heating capacity P rated h Minimum heating capacity nom Nominal heating capacity useful efficiency pl Minimum capacity useful efficiency e...

Страница 13: ...to the width of the machine If belts or ropes are used a rocker arm must be used not included to prevent the pressure exerted by the same from damaging the structure of the unit Should it be necessar...

Страница 14: ...g and maintenance operations maintain the safety distances from flammable material be placed close to a flue chimney be able to be connected to the fuel source be close to an electrical socket allow f...

Страница 15: ...ter wall with delivery on 3 sides In the corner with delivery on 2 sides Any restrictions deriving from specific Laws and regulations must also be observed for example regarding fires Refer to the des...

Страница 16: ...e upper surface of the plenum can not be stepped on Air can not be spread from only one side of the plenum GENERAL INFORMATION ACCESSORIES Any accessories must be original To install them follow the i...

Страница 17: ...ut hole TYPE 1 2 3 pre cut hole mm 150 150 300 1 Pre cut hole 2 Circular fitting with stop not supplied 3 Secondary channelling not supplied INSTALLATION INFORMATION FUEL CONNECTION The machine should...

Страница 18: ...he entire smoke duct must not rest on the appliance The flue must ensure the minimum depression required by the current technical standards considering zero pressure to the connection with the fume du...

Страница 19: ...be installed in accordance with the regulations in force and be used only in a sufficiently ventilated area Check that the combustion air inlet is always free from any obstacles leaves sheets of pape...

Страница 20: ...y sized according to the regulations in force Always connect the earthing system taking care to leave the earth wire slightly longer that the other wires so that in case of accidental pulling the latt...

Страница 21: ...is an integral part of this instruction manual We recommend keeping it carefully together with the other documents Should this copy be mislaid ask the Manufacturer for a duplicate notifying the serial...

Страница 22: ...thermostat reset button 6 Room thermostat adjustment knob INSTALLATION INFORMATION FUEL TANK Type 1 and 2 appliances feature a built in tank The type 3 appliance for reasons of operating autonomy mus...

Страница 23: ...tected and solved In case of doubt please contact the closest Authorized Assistance Centre which will provide you with the necessary technical assistance INSTALLATION INFORMATION VENTILATION HEATING O...

Страница 24: ...valve and make sure the burner stops During the first start up cycle the burner may stop due to the lack of fuel supply In this case wait at least 30 seconds and after unblocking the burner by pressi...

Страница 25: ...the burner turns off Do not intervene on the sealings made in the factory check that the engine electric absorption value does not exceed the value specified in the plate make sure that the fan operat...

Страница 26: ...rder for the machine to properly work and be maintained we suggest performing the regular cleaning and maintenance operations according to the indications in the following paragraphs Cleaning and main...

Страница 27: ...Check the functionality of the safety thermostat at least quarterly Simulate its intervention and it should be verified that the burner goes out MAINTENANCE INFORMATION SECURITY CONTROL Periodically...

Страница 28: ...d the door 10 after loosening the nuts 9 Using a brush clean the inside of the smoke pipes Using an aspirator remove any soot that has deposited in the rear flue gas collector and in the combustion ch...

Страница 29: ...ce Toode Produsul V ro bok Proizvod BF 35 BF 75 BF 105 Wedeclarethatitiscompliantwith Sidichiarache conformea EswirdalskonformmitdenfolgendenNormen erkl rt Sedeclaraqueest enconformidadcon Nousd claro...

Страница 30: ...Poland Dantherm Sp z o o 5A 62 023 Dantherm LLC ul Transportnaya 22 ownership 2 142802 STUPINO Moscow region Russia 22 2 142802 Dantherm China LTD Unit 2B 512 Yunchuan Rd Shanghai 201906 China Danther...

Отзывы: