background image

 

 

Built in NI-HI rechargeable battery is available to provide power supply nearly 5hours automatically after 

power off; 

 

AC and DC dual use are available for 24-hours-a-day normal guard;   

 

Main unit anti-tamper and low-voltage detecting function. 

 

3 Technical Parameter 
 
 
 
 
 
 
 
 
 
 
4 Factory Default 

 

defence zone 

Arm 

At 

Home 

Type 

Alarm 

Conditions 

Siren 

defence zone 1 

Valid 

 

Real-time 

Door lock alarm 

On 

defence zone 2 

Valid 

 

Real-time 

Hall alarm 

On 

defence zone 3 (wired) 

Valid 

Valid 

Real-time 

Window alarm 

On 

defence zone 4 (wired) 

Valid 

Valid 

Real-time 

Balcony alarm 

On 

defence zone 5 (wired) 

Valid 

Valid 

24 hours 

Fire alarm 

On 

defence zone 6 (wired) 

Valid 

Valid 

24 hours 

Gas alarm 

On 

Remote control emergency key 

Valid 

Valid 

24 hours 

Help alarm 

 

 

Programming password: 

8888 

Remote Control: 

Enabled 

Operation Password: 

1234 

Ringing Times: 

Once 

Siren Duration: 

180 seconds 

Warning Siren: 

Disabled 

 

 

5 Installation   
 

 

Main Unit Installation 

 

Be careful to keep it away from large metal objects or household appliances which may cause high frequency 

interference, as well as barriers such as reinforced concrete walls and fire doors. 

 

Input Voltage: 

 

DC9V~12V 

Standby Current: 

 

<55mA 

Alarm Current: 

 

<450mA 

Wireless Frequency: 

 

315/433.92

MHz, 2262/4.7MΩ 

GSM Frequency: 

 

900/1800/1900MHz 

Backup Battery: 

 

NI-HI AAA*6    DC7.4V 

Alarm Loudness: 

 

110dB 

Содержание YA-300-GSM

Страница 1: ...well as residential communities 2 Function Introduction 4 wired and 6 wireless defence zones Can preset and store 6 voice phones and 3 message phones Remote two way intercom Built in intercom speaker...

Страница 2: ...rm On defence zone 5 wired Valid Valid 24 hours Fire alarm On defence zone 6 wired Valid Valid 24 hours Gas alarm On Remote control emergency key Valid Valid 24 hours Help alarm Programming password 8...

Страница 3: ...ion Step 2 Fit the GSM card into the card socket properly Step 3 Push the card socket as close direction until it is fit firmly 6 Main Unit Settings Prompt Message Function Operation Instructions Note...

Страница 4: ...eep a long sound lights were flashing and finally release the button Host settings have all been removed restoring the value of a successful factory Voice Record In the status of disarm press Set for...

Страница 5: ...l code pairing status press Set once again and the indicator of defence zone 1 goes on Prompt trigger detector then take a sensor required for code pairing and trigger an alarm to emit a wireless sign...

Страница 6: ...eration Instructions Notes Enter Programming Enter password Long beep Exit Settings Hang up directly Short Beep Operation Password 30 new password modified Factory default 1234 Programming Password 31...

Страница 7: ...amming password into the new password 0000 SMS Command 8888310000 Operation Password after dialing the SIM card number by mobile phone or fixed phone if you enter the operation password factory defaul...

Страница 8: ...t the address codes of message receiving numbers from the first group the third group Set Number Delete number Illustration X indicates the set message receiving phone number set 13811111111 to be the...

Страница 9: ...y B arm at home stay at home 0 indicates invalid no alarm 1 indicates valid enable alarm Illustration A indicates the number of defence zone B indicates arm at home is valid invalid set the defence zo...

Страница 10: ...thod 33 22 45 SMS Command 8888332245 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm Y...

Страница 11: ...sensors of alerters are always working when the sensor is triggered by door fire gas leak etc the alarm system will sound the alarm After you have done these operations the indicator of Arm on the ma...

Страница 12: ...conds 5 key Open 1st home appliance Open relay 6 key Close 1st home appliance Close relay 7 key Open 2nd home appliance 8 key Close 2nd home appliance 9 key Open mini siren or wireless siren If need t...

Страница 13: ...rm unit and make a alarm Pair the Siren Wireless siren can only accept the alarm unit signal control after paired Pairing method According to the wireless siren manual make the siren stay the code pai...

Страница 14: ...Is the PIN code of SIM card set Cancel it Power indicator always flickering Is the network signal strong enough Change place The signal of Unicom card is weaker than that of China Mobile Alarm failur...

Страница 15: ...approval and consent of relevant authorities please do not set 999 110 or the alarm phone number of police station for this main unit 10 Standard Package Main Panel 1pcs Wireless Infrared Detector 1p...

Отзывы: