      [7] key: Open 2nd    home appliance. 

      [8] key: Close 2nd    home appliance. 

      [9] key: Open mini siren or wireless siren. If need to close siren, press any one of 1/2/3/4 keys. 

      SMS command: 1234 [1-9] # 

 

■  

Home Appliance Control 

 

Home Appliance Switch Pairing

Home appliance switch can only accept the alarm unit signal control after 

paired.   

Pairing method: Refer to household appliance switch manaul, make the appliance into the code-pair state,. 

Then enter into the remote control setting, press 5-8 key operating the alarm unit send out on or off signals to the 

appliance, paired them is ok. 

 

Signal encryption

Encrypted wireless signals,can reduce the home appliance mis-operate frequency that 

caused by other signals interference. 

Encryption method: Enter into system setting, input 73 + XX (2-bit encryption of data) + # 

SMS operation: 888873XX # 

(Home  appliance  control  settings  have  a  certain  complexity,  recommend  that  users  complete  purchase 

directly from the manufacturer).

 

■   

Connect Wireless Siren (Option Function)

 

 

This alarm unit can connect wireless siren, to avoid big sound noise to disturb the owner when the siren install 

near the alarm unit and make a alarm. 

Pair the Siren : Wireless siren can only accept the alarm unit signal control after paired.   

Pairing  method:  According  to  the  wireless  siren  manual,  make  the  siren  stay  the  code-pair  state,then 

continue to press 4 times of set button on the alarm unit, sending "open wireless siren" signal to siren,then to pair 

them. 

Paired  wireless  siren,  will  sound  when  the  alarm  unit  alarming,  and  stop  to  sound  when  the  alarm  unit 

disarm. (Due to wireless control, there may be some time delay) 

 

Signal  Encryption

Encrypted  wireless  signals,can  reduce  the  wireless  siren  mis-alarm  frequency  that 

caused by other signals interference. 

Encryption method: Enter into system setting, input 74 + XX (2-bit encryption of data) + # 

SMS operation: 888874XX # 

(Wireless  siren  control  settings  have  a  certain  complexity,  recommend  that  users  complete  purchase 

directly from the manufacturer). 

 

 

Remote Control Programming

 

 

     

Dial the number associated to the alarm main unit by phone (mobile phone), and after one ringing cycle, you 

can hear a voice prompt “Please enter the password”; enter the password by phone keys (factory default of remote 
control password: 8888). If the password are correct, you will hear a long “beep” prompt tone; if it is wrong, you will 
hear a prompt “the password is invalid, please enter it again”. 

 

9 Maintenance 
 

12 

Содержание YA-300-GSM

Страница 1: ...well as residential communities 2 Function Introduction 4 wired and 6 wireless defence zones Can preset and store 6 voice phones and 3 message phones Remote two way intercom Built in intercom speaker...

Страница 2: ...rm On defence zone 5 wired Valid Valid 24 hours Fire alarm On defence zone 6 wired Valid Valid 24 hours Gas alarm On Remote control emergency key Valid Valid 24 hours Help alarm Programming password 8...

Страница 3: ...ion Step 2 Fit the GSM card into the card socket properly Step 3 Push the card socket as close direction until it is fit firmly 6 Main Unit Settings Prompt Message Function Operation Instructions Note...

Страница 4: ...eep a long sound lights were flashing and finally release the button Host settings have all been removed restoring the value of a successful factory Voice Record In the status of disarm press Set for...

Страница 5: ...l code pairing status press Set once again and the indicator of defence zone 1 goes on Prompt trigger detector then take a sensor required for code pairing and trigger an alarm to emit a wireless sign...

Страница 6: ...eration Instructions Notes Enter Programming Enter password Long beep Exit Settings Hang up directly Short Beep Operation Password 30 new password modified Factory default 1234 Programming Password 31...

Страница 7: ...amming password into the new password 0000 SMS Command 8888310000 Operation Password after dialing the SIM card number by mobile phone or fixed phone if you enter the operation password factory defaul...

Страница 8: ...t the address codes of message receiving numbers from the first group the third group Set Number Delete number Illustration X indicates the set message receiving phone number set 13811111111 to be the...

Страница 9: ...y B arm at home stay at home 0 indicates invalid no alarm 1 indicates valid enable alarm Illustration A indicates the number of defence zone B indicates arm at home is valid invalid set the defence zo...

Страница 10: ...thod 33 22 45 SMS Command 8888332245 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm Y...

Страница 11: ...sensors of alerters are always working when the sensor is triggered by door fire gas leak etc the alarm system will sound the alarm After you have done these operations the indicator of Arm on the ma...

Страница 12: ...conds 5 key Open 1st home appliance Open relay 6 key Close 1st home appliance Close relay 7 key Open 2nd home appliance 8 key Close 2nd home appliance 9 key Open mini siren or wireless siren If need t...

Страница 13: ...rm unit and make a alarm Pair the Siren Wireless siren can only accept the alarm unit signal control after paired Pairing method According to the wireless siren manual make the siren stay the code pai...

Страница 14: ...Is the PIN code of SIM card set Cancel it Power indicator always flickering Is the network signal strong enough Change place The signal of Unicom card is weaker than that of China Mobile Alarm failur...

Страница 15: ...approval and consent of relevant authorities please do not set 999 110 or the alarm phone number of police station for this main unit 10 Standard Package Main Panel 1pcs Wireless Infrared Detector 1p...

Отзывы: