Figure 5.8 Graphic Local Control Panel (GLCP)
A. Display area
The display area is activated when the frequency converter
receives power from the mains voltage, a DC bus terminal
or an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application. Select options in the
Quick Menu
Q3-13 Display Settings
.
Display
Parameter number
Default setting
1
0-20
[1602] Reference [%]
2
0-21
[1614] Motor Current
3
0-22
[1610] Power [kW]
4
0-23
[1613] Frequency
5
0-24
[1502] kWh Counter
Table 5.8 Legend to
, Display Area
B. Display menu keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation and viewing fault log data.
Key
Function
6
Status
Shows operational information.
7
Quick
Menu
Allows access to programming parameters
for initial set-up instructions and many
detailed application instructions.
8
Main Menu Allows access to all programming
parameters.
9
Alarm Log
Displays a list of current warnings, the last 10
alarms and the maintenance log.
Table 5.9 Legend to
, Display Menu Keys
C. Navigation keys and LEDs
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local operation. There are also
three adjustable frequency drive status indicator lights in
this area.
Key
Function
10 Back
Reverts to the previous step or list in the
menu structure.
11 Cancel
Cancels the last change or command as long
as the display mode has not changed.
12 Info
Press for a definition of the function being
displayed.
13 Navigation
Keys
Use the four navigation keys to move
between items in the menu.
14 OK
Press to access parameter groups or to
enable a selection.
Table 5.10 Legend to
, Navigation Keys
Indicator
Light
Function
15 On
Green
The ON light activates when the
frequency converter receives
power from the mains voltage, a
DC bus terminal or an external 24
V supply.
16 Warn.
Yellow
When warning conditions are met,
the yellow WARN light turns on
and text appears in the display
area identifying the problem.
17 Alarm
Red
A fault condition causes the red
alarm light to flash and an alarm
text is displayed.
Table 5.11 Legend to
, Indicator Lights (LEDs)
Commissioning
VLT
®
Midi Drive FC 280
26