Bit (Hex)
Alarm word (Par. 16-90)
CIP Classification
00000001
Brake check
-
00000002
Power card over temperature
MAR
00000004
Earth fault
MAU
00000008
Ctrl. card over temperature
-
00000010
Control word timeout
MAR
00000020
Torque limit
MAU
00000040
Over current
MAR
00000080
Motor thermistor over temp.
MAR
00000100
Motor ETR over temperature
MAR
00000200
Inverter overloaded
MAR
00000400
DC link under voltage
MAR
00000800
DC link over voltage
MAR
00001000
Short circuit
MAU
00002000
Inrush fault
MAR
00004000
Mains phase loss
MAU
00008000
AMA not OK
MAR
00010000
Live zero error
MAR
00020000
Internal fault
MAU
00040000
Brake overload
MAU
00080000
Motor phase U is missing
MAU
00100000
Motor phase V is missing
MAU
00200000
Motor phase W is missing
MAU
00400000
fieldbus fault
MAR
00800000
24V supply fault
MAU
01000000
Mains failure
MAR
02000000
1.8V supply fault
MAU
04000000
Brake resistor short circuit
MAR
08000000
Brake chopper fault
MAR
10000000
Option change
-
20000000
Drive initialized
-
40000000
Safe Stop
MAR
80000000
Mech. Brake low
-
MAR = Major Recoverable Fault
MAU = Major Unrecoverable Fault
Troubleshooting
MCA 121 EtherNet/IP
40
MG.90.J3.02 - VLT
®
is a registered Danfoss trademark
7
7
Содержание VLT MCA 121 EtherNet/IP
Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions MCA 121 EtherNet IP...
Страница 58: ...www danfoss com drives MG90J302 130R0430 MG90J302 Rev 2011 03 29...
Страница 59: ......