Pa
r.
No
.
#
Pa
ramete
r description
Def
ault value
4 s
et
-u
p
Change during
ope
rat
ion
Con
ver-
sio
n index
Typ
e
21
-1*
Ex
t.
CL 1
Ref.
/Fb.
21-
10
Ex
t.
1 Re
f.
/F
ee
db
ac
k U
ni
t
[1
] %
Al
l set-
ups
TRUE
-
Uint8
21-
11
Ex
t.
1 Mini
mum Referen
ce
0.
000 E
xtPI
D
1U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
12
Ex
t. 1 Max
im
um
R
efe
rence
100.
000
Ex
tP
ID
1Uni
t
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
13
Ex
t.
1
Re
fere
nce So
urce
[0] No
functio
n
Al
l set-ups
TRU
E
-
Ui
nt8
21-
14
Ex
t. 1 Fee
dback So
ur
ce
[0]
No functio
n
Al
l se
t-up
s
TR
U
E
-
U
int8
21-
15
Ex
t.
1 Se
tpoint
0.
000 E
xtPI
D
1U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
17
Ex
t. 1 R
efe
rence
[Uni
t]
0.
000 E
xtPI
D
1U
nit
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
18
Ex
t. 1 Feed
back [U
ni
t]
0.
000 E
xtPI
D
1U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
19
Ex
t.
1 Output
[
%
]
0 %
Al
l set-ups
TRU
E
0
Int32
21
-2*
Ex
t.
CL 1
P
ID
21-
20
Ex
t.
1 No
rmal/Inv
erse
Contro
l
[0] No
rmal
Al
l set-
ups
TRUE
-
Uint8
21-
21
Ex
t.
1 P
ropo
rti
on
al Gain
0.
01 N/
A
Al
l set-ups
TRU
E
-2
Ui
nt1
6
21-
22
Ex
t. 1 Integ
ral Time
10
,00
0.0
0 s
Al
l se
t-up
s
TR
U
E
-2
U
int32
21-
23
Ex
t.
1 Diffe
rent
ia
tio
n Tim
e
0.
00 s
Al
l set-ups
TRU
E
-2
Ui
nt1
6
21-
24
Ex
t. 1 Dif. Gain Limi
t
5.0 N/
A
Al
l se
t-up
s
TR
U
E
-1
U
int16
21
-3*
Ex
t.
CL 2
Ref.
/Fb.
21-
30
Ex
t.
2 Re
f.
/F
ee
db
ac
k U
ni
t
[1
] %
Al
l set-
ups
TRUE
-
Uint8
21-
31
Ex
t.
2 Mini
mum Referen
ce
0.
000 E
xtPI
D
2U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
32
Ex
t. 2 Max
im
um
R
efe
rence
100.
000
Ex
tP
ID
2Uni
t
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
33
Ex
t.
2
Re
fere
nce So
urce
[0] No
functio
n
Al
l set-ups
TRU
E
-
Ui
nt8
21-
34
Ex
t. 2 Fee
dback So
ur
ce
[0]
No functio
n
Al
l se
t-up
s
TR
U
E
-
U
int8
21-
35
Ex
t.
2 Se
tpoint
0.
000 E
xtPI
D
2U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
37
Ex
t. 2 R
efe
rence
[Uni
t]
0.
000 E
xtPI
D
2U
nit
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
38
Ex
t. 2 Feed
back [U
ni
t]
0.
000 E
xtPI
D
2U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
39
Ex
t.
2 Output
[
%
]
0 %
Al
l set-ups
TRU
E
0
Int32
21
-4*
Ex
t.
CL 2
P
ID
21-
40
Ex
t.
2 No
rmal/Inv
erse
Contro
l
[0] No
rmal
Al
l set-
ups
TRUE
-
Uint8
21-
41
Ex
t.
2 P
ropo
rti
on
al Gain
0.
01 N/
A
Al
l set-ups
TRU
E
-2
Ui
nt1
6
21-
42
Ex
t. 2 Integ
ral Time
10
,00
0.0
0 s
Al
l se
t-up
s
TR
U
E
-2
U
int32
21-
43
Ex
t.
2 Diffe
rent
ia
tio
n Tim
e
0.
00 s
Al
l set-ups
TRU
E
-2
Ui
nt1
6
21-
44
Ex
t. 2 Dif. Gain Limi
t
5.0 N/
A
Al
l se
t-up
s
TR
U
E
-1
U
int16
21
-5*
Ex
t.
CL 3
Ref.
/Fb.
21-
50
Ex
t.
3 Re
f.
/F
ee
db
ac
k U
ni
t
[1
] %
Al
l set-
ups
TRUE
-
Uint8
21-
51
Ex
t.
3 Mini
mum Referen
ce
0.
000 E
xtPI
D
3U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
52
Ex
t. 3 Max
im
um
R
efe
rence
100.
000
Ex
tP
ID
3Uni
t
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
53
Ex
t.
3
Re
fere
nce So
urce
[0] No
functio
n
Al
l set-ups
TRU
E
-
Ui
nt8
21-
54
Ex
t. 3 Fee
dback So
ur
ce
[0]
No functio
n
Al
l se
t-up
s
TR
U
E
-
U
int8
21-
55
Ex
t.
3 Se
tpoint
0.
000 E
xtPI
D
3U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
57
Ex
t. 3 R
efe
rence
[Uni
t]
0.
000 E
xtPI
D
3U
nit
Al
l se
t-up
s
TR
U
E
-3
Int32
21-
58
Ex
t. 3 Feed
back [U
ni
t]
0.
000 E
xtPI
D
3U
nit
Al
l set-ups
TRU
E
-3
Int32
21-
59
Ex
t. 3 Outp
ut
[
%
]
0 %
Al
l set-
ups
TRUE
0
Int32
6.2.18.
21-** Ext. Closed-loop
6. How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
122
MG.11.A4.22 - VLT
®
is a registered Danfoss trademark
6
Содержание VLT HVAC
Страница 10: ...2 Introduction VLT HVAC Drive Instruction Manual 10 MG 11 A4 22 VLT is a registered Danfoss trademark 2...
Страница 130: ...7 Troubleshooting VLT HVAC Drive Instruction Manual 130 MG 11 A4 22 VLT is a registered Danfoss trademark 7...
Страница 138: ...8 Specifications VLT HVAC Drive Instruction Manual 138 MG 11 A4 22 VLT is a registered Danfoss trademark 8...