
Pa
r.
No
.
#
Pa
ramete
r description
Def
ault value
4 s
et
-u
p
Change during
ope
rat
ion
Con
ver-
sio
n index
Typ
e
8-
0* Gen
er
al Set
ti
n
g
s
8-0
1
Cont
rol Sit
e
[0]
Di
gi
tal
an
d ctrl
.w
ord
Al
l set-
ups
TRUE
-
Uint8
8-0
2
Cont
rol
Source
nul
l
Al
l set-ups
TRU
E
-
Ui
nt8
8-
03
Cont
rol Tim
eout
T
ime
Ex
pressionLimit
1 set-
up
TRUE
-1
Uint32
8-0
4
Cont
rol
Ti
meo
ut F
uncti
on
[0
] O
ff
1 s
et
-u
p
TRU
E
-
Ui
nt8
8-
05
En
d-
of-
Ti
m
eo
ut F
uncti
on
[1
]
Resu
m
e set
-up
1
set-
up
TRUE
-
U
int8
8-0
6
Re
set Contro
l Time
out
[0]
Do
n
ot re
se
t
Al
l set-ups
TRU
E
-
Ui
nt8
8-0
7
Dia
gnosis Trigger
[0
] Disa
ble
2 s
et
-u
ps
TRU
E
-
Ui
nt8
8-
1* Cont
ro
l Set
ti
n
g
s
8-1
0
Cont
rol Pr
ofile
[0] FC
pr
of
ile
Al
l set-
ups
TRUE
-
Uint8
8-1
3
Conf
igu
rabl
e
Stat
us Wo
rd STW
[1
] P
rofi
le
Def
au
lt
Al
l set-ups
TRU
E
-
Ui
nt8
8-
3*
FC Por
t Set
ti
n
gs
8-3
0
Pro
tocol
[0] FC
1 s
et
-u
p
TRU
E
-
Ui
nt8
8-
31
Addre
ss
1 N/A
1
set-
up
TRUE
0
U
int8
8-3
2
Baud R
at
e
nul
l
1 s
et
-u
p
TRU
E
-
Ui
nt8
8-3
3
Pa
rity /
Sto
p
Bi
ts
nul
l
1 set-
up
TRUE
-
U
int8
8-3
5
Mi
nimum Respo
nse
D
el
ay
10 ms
1 s
et
-u
p
TRU
E
-3
Ui
nt1
6
8-
36
Max Respo
nse De
la
y
Ex
pressionLimi
t
1 set-
up
TRUE
-3
Uint16
8-3
7
Max Inter-Cha
r Delay
Ex
pressionLimit
1 s
et
-u
p
TRU
E
-5
Ui
nt1
6
8-
4*
FC MC pr
o
tocol set
8-4
0
Te
le
gr
am
Se
le
ctio
n
[1] Stand
ard
tel
eg
ram 1
2 s
et
-u
ps
TRU
E
-
Ui
nt8
8-
5* Di
git
al/
Bus
8-5
0
Coa
sting Se
le
ct
[3
] L
ogi
c O
R
Al
l set-ups
TRU
E
-
Ui
nt8
8-5
2
DC
Brake
S
ele
ct
[3
] Lo
gi
c OR
Al
l se
t-up
s
TR
U
E
-
U
int8
8-5
3
Sta
rt S
el
ect
[3
] L
ogi
c O
R
Al
l set-ups
TRU
E
-
Ui
nt8
8-
54
Re
versi
ng Se
lec
t
[0
]
Di
git
al i
nput
All
set-
ups
TRU
E
-
Ui
nt8
8-5
5
Set-up Select
[3
] L
ogi
c O
R
Al
l set-ups
TRU
E
-
Ui
nt8
8-5
6
Pre
set Ref
ere
nce
Se
lect
[3
] L
ogi
c O
R
Al
l set-ups
TRU
E
-
Ui
nt8
8-
7* BACn
et
8-7
0
BACnet
Device In
stance
1 N/A
1 set-
up
TRUE
0
U
int32
8-7
2
MS/
TP Max
M
asters
127 N/A
1 s
et
-u
p
TRU
E
0
Ui
nt8
8-7
3
MS/
TP Max Info
Fra
m
es
1 N/A
1
set-
up
TRUE
0
U
int16
8-7
4
"I
-Am
" Service
[0] Send
at po
w
er-
up
1 s
et
-u
p
TRU
E
-
Ui
nt8
8-7
5
In
itia
liza
tio
n Pa
sswo
rd
0 N/A
1 s
et
-u
p
TRU
E
0
Vi
sStr[20]
8-
8* FC P
o
rt
D
iagn
o
sti
cs
8-8
0
Bus Me
ssage
Coun
t
0 N/A
Al
l set-
ups
TRUE
0
Uint32
8-8
1
Bus E
rror
Co
unt
0 N/A
Al
l set-ups
TRU
E
0
Ui
nt3
2
8-
82
Slave
Message Co
unt
0 N/A
All
set-
ups
TRUE
0
Uint32
8-8
3
Slave
Error Coun
t
0 N/A
Al
l set-ups
TRU
E
0
Ui
nt3
2
8-
9*
Bus Jog /
Feed
bac
k
8-9
0
Bus Jog 1
Sp
ee
d
100 R
PM
Al
l set-ups
TRU
E
67
Ui
nt1
6
8-9
1
Bus Jo
g 2
Sp
ee
d
200 R
PM
Al
l se
t-up
s
TR
U
E
67
U
int16
8-9
4
Bus Feed
back 1
0 N/A
1 s
et
-u
p
TRU
E
0
N2
8-9
5
Bus Feed
back 2
0 N/A
1
se
t-up
TR
UE
0
N
2
8-9
6
Bus Feed
back 3
0 N/A
1 s
et
-u
p
TRU
E
0
N2
6.2.8.
8-** Comm. and Options
6. How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
110
MG.11.A4.22 - VLT
®
is a registered Danfoss trademark
6
Содержание VLT HVAC
Страница 10: ...2 Introduction VLT HVAC Drive Instruction Manual 10 MG 11 A4 22 VLT is a registered Danfoss trademark 2...
Страница 130: ...7 Troubleshooting VLT HVAC Drive Instruction Manual 130 MG 11 A4 22 VLT is a registered Danfoss trademark 7...
Страница 138: ...8 Specifications VLT HVAC Drive Instruction Manual 138 MG 11 A4 22 VLT is a registered Danfoss trademark 8...