Drive
P11K
P15K
P18K
P22K
P30K
P37K
P45K
Maximum cable size in terminals
(mains, motor) [m
2
(AWG)]
16 (6)
35 (2)
35 (2)
50 (1)
50 (1)
95 (0)
120 (4/0)
Output current - 40°C (104°F) ambient temperature
Continuous (3x200–240 V) [A]
42.0
59.4
74.8
88.0
115.0
143.0
170.0
Intermittent (3x200–240 V) [A]
46.2
65.3
82.3
96.8
126.5
157.3
187.0
Maximum input current
Continuous 3x200–240 V) [A]
41.0/38.2
52.7
65.0
76.0
103.7
127.9
153.0
Intermittent (3x200–240V) [A]
45.1/42.0
58.0
71.5
83.7
114.1
140.7
168.3
Maximum mains fuses
See
3.2.4.5 Recommendation of Fuses and Circuit Breakers
Estimated power loss [W], Best
case/typical
(1)
369/386
512
697
879
1149
1390
1500
Weight enclosure protection rat-
ing IP20 [kg (lb)]
9.5 (20.9)
24.5 (54)
24.5 (54)
36.0 (79.4)
36.0 (79.4)
51.0
(112.4)
51.0
(112.4)
Efficiency [%], best case/typical
(2)
97.2/97.1
97.0
97.1
96.8
97.1
97.1
97.3
Output current - 50°C (122°F) ambient temperature
Continuous (3x200–240 V) [A]
33.0
41.6
52.4
61.6
80.5
100.1
119
Intermittent (3x200–240 V) [A]
36.3
45.8
57.6
67.8
88.6
110.1
130.9
1
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and typical control card power consump-
tions are included. For power loss data according to EN 50598-2, refer to Danfoss
website.
2
Efficiency measured at nominal current. For energy efficiency class, see
. For part load losses, see Danfoss
website.
6.1.2 3x380–480 V AC
Table 22: 3x380–480 V AC, 0.37–15 kW (0.5–20 hp), Enclosure Sizes H1–H4
Drive
PK37
PK75
P1K5
P2K2
P3K0
P4K0
P5K5
P7K5
P11K
P15K
Typical shaft output [kW]
0.37
0.75
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
Typical shaft output [hp]
0.5
1.0
2.0
3.0
4.0
5.0
7.5
10.0
15.0
20.0
Protection rating IP20
H1
H1
H1
H2
H2
H2
H3
H3
H4
H4
Maximum cable size in terminals
(mains, motor) [mm
2
(AWG)]
4 (10)
4 (10)
4 (10)
4 (10)
4 (10)
4 (10)
4 (10)
4 (10)
16 (6)
16 (6)
Output current - 40°C (104°F) ambient temperature
Continuous (3x380–440 V)[A]
1.2
2.2
3.7
5.3
7.2
9.0
12.0
15.5
23.0
31.0
Intermittent (3x380–440 V) [A]
1.3
2.4
4.1
5.8
7.9
9.9
13.2
17.1
25.3
34.0
Continuous (3x441–480 V) [A]
1.1
2.1
3.4
4.8
6.3
8.2
11.0
14.0
21.0
27.0
Intermittent (3x441–480 V) [A]
1.2
2.3
3.7
5.3
6.9
9.0
12.1
15.4
23.1
29.7
Maximum input current
Specifications
Operating Guide | VLT® HVAC Basic Drive FC 101
AQ275641848264en-000101 / 132R0078| 67
Danfoss A/S © 2019.11
Содержание VLT HVAC Basic Drive FC 101
Страница 1: ...Operating Guide VLT HVAC Basic Drive FC 101...
Страница 2: ......
Страница 82: ...Operating Guide VLT HVAC Basic Drive FC 101 AQ275641848264en 000101 132R0078 82 Danfoss A S 2019 11...
Страница 83: ...Operating Guide VLT HVAC Basic Drive FC 101 AQ275641848264en 000101 132R0078 83 Danfoss A S 2019 11...