14-88
Option Data Storage
0 N/A
2 set-ups
TRUE
0
Uint16
14-89
Option Detection
[0] Protect Option
Config.
1 set-up
TRUE
–
Uint8
14-9* Fault Settings
14-90
Fault Level
ExpressionLimit
1 set-up
TRUE
–
Uint8
5.3.13 15-** Drive Information
Par-
ameter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
15-0* Operating Data
15-00
Operating hours
0 h
All set-ups
FALSE
74
Uint32
15-01
Running Hours
0 h
All set-ups
FALSE
74
Uint32
15-02
kWh Counter
0 kWh
All set-ups
FALSE
75
Uint32
15-03
Power Up's
0 N/A
All set-ups
FALSE
0
Uint32
15-04
Over Temp's
0 N/A
All set-ups
FALSE
0
Uint16
15-05
Over Volt's
0 N/A
All set-ups
FALSE
0
Uint16
15-06
Reset kWh Counter
[0] Do not reset
All set-ups
TRUE
–
Uint8
15-07
Reset Running Hours Counter
[0] Do not reset
All set-ups
TRUE
–
Uint8
15-1* Data Log Settings
15-10
Logging Source
0
2 set-ups
TRUE
–
Uint16
15-11
Logging Interval
ExpressionLimit
2 set-ups
TRUE
-3
TimD
15-12
Trigger Event
[0] False
1 set-up
TRUE
–
Uint8
15-13
Logging Mode
[0] Log always
2 set-ups
TRUE
–
Uint8
15-14
Samples Before Trigger
50 N/A
2 set-ups
TRUE
0
Uint8
15-2* Historic Log
15-20
Historic Log: Event
0 N/A
All set-ups
FALSE
0
Uint8
15-21
Historic Log: Value
0 N/A
All set-ups
FALSE
0
Uint32
15-22
Historic Log: Time
0 ms
All set-ups
FALSE
-3
Uint32
15-3* Fault Log
15-30
Fault Log: Error Code
0 N/A
All set-ups
FALSE
0
Uint16
15-31
Fault Log: Value
0 N/A
All set-ups
FALSE
0
Int16
15-32
Fault Log: Time
0 s
All set-ups
FALSE
0
Uint32
15-4* Drive Identification
15-40
FC Type
0 N/A
All set-ups
FALSE
0
VisStr[6]
15-41
Power Section
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-42
Voltage
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-43
Software Version
0 N/A
All set-ups
FALSE
0
VisStr[5]
15-44
Ordered Typecode String
0 N/A
All set-ups
FALSE
0
VisStr[40]
15-45
Actual Typecode String
0 N/A
All set-ups
FALSE
0
VisStr[40]
15-46
Frequency Converter Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-47
Power Card Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-48
LCP Id No
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-49
SW ID Control Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-50
SW ID Power Card
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-51
Frequency Converter Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[10]
15-53
Power Card Serial Number
0 N/A
All set-ups
FALSE
0
VisStr[19]
15-58
Smart Setup Filename
ExpressionLimit
All set-ups
TRUE
0
VisStr[20]
15-59
CSIV Filename
ExpressionLimit
1 set-up
FALSE
0
VisStr[16]
15-6* Option Ident
15-60
Option Mounted
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-61
Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-62
Option Ordering No
0 N/A
All set-ups
FALSE
0
VisStr[8]
15-63
Option Serial No
0 N/A
All set-ups
FALSE
0
VisStr[18]
Programming
Operating Guide
MG04F402
Danfoss A/S © 05/2016 All rights reserved.