6-35
Term. X30/11 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-36
Term. X30/11 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-41
Terminal X30/12 High Voltage
10 V
All set-ups
TRUE
-2
Int16
6-44
Term. X30/12 Low Ref./Feedb. Value
0 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
6-45
Term. X30/12 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-46
Term. X30/12 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-5* Analog Output 1
6-50
Terminal 42 Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
6-51
Terminal 42 Output Min Scale
0 %
All set-ups
TRUE
-2
Int16
6-52
Terminal 42 Output Max Scale
100 %
All set-ups
TRUE
-2
Int16
6-53
Term 42 Output Bus Ctrl
0 %
All set-ups
TRUE
-2
N2
6-54
Terminal 42 Output Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
6-55
Analog Output Filter
[0] Off
1 set-up
TRUE
–
Uint8
6-6* Analog Output 2
6-60
Terminal X30/8 Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
6-61
Terminal X30/8 Min. Scale
0 %
All set-ups
TRUE
-2
Int16
6-62
Terminal X30/8 Max. Scale
100 %
All set-ups
TRUE
-2
Int16
6-63
Terminal X30/8 Bus Control
0 %
All set-ups
TRUE
-2
N2
6-64
Terminal X30/8 Output Timeout
Preset
0 %
1 set-up
TRUE
-2
Uint16
6-7* Analog Output 3
6-70
Terminal X45/1 Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
6-71
Terminal X45/1 Min. Scale
0 %
All set-ups
TRUE
-2
Int16
6-72
Terminal X45/1 Max. Scale
100 %
All set-ups
TRUE
-2
Int16
6-73
Terminal X45/1 Bus Control
0 %
All set-ups
TRUE
-2
N2
6-74
Terminal X45/1 Output Timeout
Preset
0 %
1 set-up
TRUE
-2
Uint16
6-8* Analog Output 4
6-80
Terminal X45/3 Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
6-81
Terminal X45/3 Min. Scale
0 %
All set-ups
TRUE
-2
Int16
6-82
Terminal X45/3 Max. Scale
100 %
All set-ups
TRUE
-2
Int16
6-83
Terminal X45/3 Bus Control
0 %
All set-ups
TRUE
-2
N2
6-84
Terminal X45/3 Output Timeout
Preset
0 %
1 set-up
TRUE
-2
Uint16
5.3.8 7-** Controllers
Par-
ameter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
ExpressionLimit
All set-ups
FALSE
–
Uint8
7-01
Speed PID Droop
0 RPM
All set-ups
TRUE
67
Uint16
7-02
Speed PID Proportional Gain
ExpressionLimit
All set-ups
TRUE
-3
Uint16
7-03
Speed PID Integral Time
ExpressionLimit
All set-ups
TRUE
-4
Uint32
7-04
Speed PID Differentiation Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
7-05
Speed PID Diff. Gain Limit
5 N/A
All set-ups
TRUE
-1
Uint16
7-06
Speed PID Lowpass Filter Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
7-07
Speed PID Feedback Gear Ratio
1 N/A
All set-ups
FALSE
-4
Uint32
7-08
Speed PID Accel. Feed Forward
Factor
0 %
All set-ups
TRUE
0
Uint16
7-09
Speed PID Error Correction w/ Ramp
300 RPM
All set-ups
TRUE
67
Uint32
Programming
VLT
®
Decentral Drive FCD 302
50
Danfoss A/S © 05/2016 All rights reserved.
MG04F402
5
5