5.3.12 14-** Special Functions
Par-
ameter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
14-0* Inverter Switching
14-00
Switching Pattern
[1] SFAVM
All set-ups
TRUE
–
Uint8
14-01
Switching Frequency
ExpressionLimit
All set-ups
TRUE
–
Uint8
14-03
Overmodulation
[1] On
All set-ups
FALSE
–
Uint8
14-04
PWM Random
[0] Off
All set-ups
TRUE
–
Uint8
14-06
Dead Time Compensation
[1] On
All set-ups
TRUE
–
Uint8
14-1* Mains On/Off
14-10
Mains Failure
[0] No function
All set-ups
TRUE
–
Uint8
14-11
Mains Voltage at Mains Fault
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-12
Function at Mains Imbalance
[0] Trip
All set-ups
TRUE
–
Uint8
14-14
Kin. Backup Time Out
60 s
All set-ups
TRUE
0
Uint8
14-15
Kin. Backup Trip Recovery Level
ExpressionLimit
All set-ups
TRUE
-3
Uint32
14-16
Kin. Backup Gain
100 %
All set-ups
TRUE
0
Uint32
14-2* Trip Reset
14-20
Reset Mode
[0] Manual reset
All set-ups
TRUE
–
Uint8
14-21
Automatic Restart Time
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-22
Operation Mode
[0] Normal
operation
All set-ups
TRUE
–
Uint8
14-23
Typecode Setting
ExpressionLimit
2 set-ups
FALSE
–
Uint8
14-24
Trip Delay at Current Limit
60 s
All set-ups
TRUE
0
Uint8
14-25
Trip Delay at Torque Limit
60 s
All set-ups
TRUE
0
Uint8
14-26
Trip Delay at Inverter Fault
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-28
Production Settings
[0] No action
All set-ups
TRUE
–
Uint8
14-29
Service Code
0 N/A
All set-ups
TRUE
0
Int32
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
100 %
All set-ups
FALSE
0
Uint16
14-31
Current Lim Ctrl, Integration Time
ExpressionLimit
All set-ups
FALSE
-3
Uint16
14-32
Current Lim Ctrl, Filter Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
14-35
Stall Protection
[1] Enabled
All set-ups
FALSE
–
Uint8
14-36
Fieldweakening Function
[0] Auto
All set-ups
TRUE
–
Uint8
14-4* Energy Optimising
14-40
VT Level
66 %
All set-ups
FALSE
0
Uint8
14-41
AEO Minimum Magnetisation
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-42
Minimum AEO Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-43
Motor Cosphi
ExpressionLimit
All set-ups
TRUE
-2
Uint16
14-5* Environment
14-50
RFI Filter
[1] On
1 set-up
FALSE
–
Uint8
14-51
DC Link Compensation
ExpressionLimit
All set-ups
TRUE
–
Uint8
14-52
Fan Control
[0] Auto
All set-ups
TRUE
–
Uint8
14-53
Fan Monitor
ExpressionLimit
All set-ups
TRUE
–
Uint8
14-55
Output Filter
[0] No Filter
All set-ups
FALSE
–
Uint8
14-56
Capacitance Output Filter
ExpressionLimit
All set-ups
FALSE
-7
Uint16
14-57
Inductance Output Filter
ExpressionLimit
All set-ups
FALSE
-6
Uint16
14-59
Actual Number of Inverter Units
ExpressionLimit
1 set-up
FALSE
0
Uint8
14-7* Compatibility
14-72
Legacy Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
14-73
Legacy Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
14-74
Leg. Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
14-8* Options
14-80
Option Supplied by External 24VDC
[1] Yes
2 set-ups
FALSE
–
Uint8
Programming
VLT
®
Decentral Drive FCD 302
54