Analog output
Number of programmable analog outputs
1
Terminal number
42
Current range at analog output
0/4 - 20 mA
Max. resistor load to common at analog output
500
Ω
Accuracy on analog output
Max. error: 0.8 % of full scale
Resolution on analog output
8 bit
The analog output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, RS-485 serial communication
Terminal number
68 (P,TX+, RX+), 69 (N,TX-, RX-)
Terminal number 61
Common for terminals 68 and 69
The RS-485 serial communication circuit is functionally seated from other central circuits and galvanically isolated from the
supply voltage (PELV).
Digital output
Programmable digital/pulse outputs
2
Terminal number
27, 29
1)
Voltage level at digital/frequency output
0 - 24 V
Max. output current (sink or source)
40 mA
Max. load at frequency output
1 k
Ω
Max. capacitive load at frequency output
10 nF
Minimum output frequency at frequency output
0 Hz
Maximum output frequency at frequency output
32 kHz
Accuracy of frequency output
Max. error: 0.1 % of full scale
Resolution of frequency outputs
12 bit
1) Terminal 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, 24 V DC output
Terminal number
12, 13
Max. load
200mA
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
Relay outputs
Programmable relay outputs
2
Relay 01 Terminal number
1-3 (break), 1-2 (make)
Max. terminal load (AC-1)
1)
on 1-2 (NO) (Resistive load)
2)3)
400V AC, 2A
Max. terminal load (AC-15)
1)
on 1-2 (NO) (Inductive load
@
cos
φ
0.4)
240V AC, 0.2A
Max. terminal load (DC-1)
1)
on 1-2 (NO) (Resistive load)
80V DC, 2A
Max. terminal load (DC-13)
1)
on 1-2 (NO) (Inductive load)
24V DC, 0.1A
Max. terminal load (AC-1)
1)
on 1-3 (NC) (Resistive load)
240V AC, 2A
Max. terminal load (AC-15)
1)
on 1-3 (NC) (Inductive load
@
cos
φ
0.4)
240V AC, 0.2A
Max. terminal load (DC-1)
1)
on 1-3 (NC) (Resistive load)
50V DC, 2A
Max. terminal load (DC-13)
1)
on 1-3 (NC) (Inductive load)
24V DC, 0.1A
Min. terminal load on 1-3 (NC), 1-2 (NO)
24V DC 10mA, 24V AC 2 mA
Environment according to EN 60664-1
overvoltage category III/pollution degree 2
Relay 02 Terminal number
4-6 (break), 4-5 (make)
Max. terminal load (AC-1)
1)
on 4-5 (NO) (Resistive load)
2)3)
400V AC, 2A
Max. terminal load (AC-15)
1)
on 4-5 (NO) (Inductive load
@
cos
φ
0.4)
240V AC, 0.2A
Max. terminal load (DC-1)
1)
on 4-5 (NO) (Resistive load)
80V DC, 2A
Max. terminal load (DC-13)
1)
on 4-5 (NO) (Inductive load)
24V DC, 0.1A
Max. terminal load (AC-1)
1)
on 4-6 (NC) (Resistive load)
240V AC, 2A
Specifications
VLT® Automation VT Drive FC 322 D-Frame Instruction Manual