6.3.10 8-** Comm. and Options
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion
index
Type
8-0* General Settings
8-01
Control Site
[0] Digital and ctrl.word
All set-ups
TRUE
-
Uint8
8-02
Control Word Source
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-03
Control Word Timeout Time
1 s
1 set-up
TRUE
-1
Uint32
8-04
Control Word Timeout Function
ExpressionLimit
1 set-up
TRUE
-
Uint8
8-05
End-of-Timeout Function
[1] Resume set-up
1 set-up
TRUE
-
Uint8
8-06
Reset Control Word Timeout
[0] Do not reset
All set-ups
TRUE
-
Uint8
8-07
Diagnosis Trigger
[0] Disable
2 set-ups
TRUE
-
Uint8
8-08
Readout Filtering
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-1* Ctrl. Word Settings
8-10
Control Word Profile
[0] FC profile
All set-ups
TRUE
-
Uint8
8-13
Configurable Status Word STW
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-14
Configurable Control Word CTW
[1] Profile default
All set-ups
TRUE
-
Uint8
8-19
Product Code
ExpressionLimit
1 set-up
TRUE
0
Uint32
8-3* FC Port Settings
8-30
Protocol
[0] FC
1 set-up
TRUE
-
Uint8
8-31
Address
1 N/A
1 set-up
TRUE
0
Uint8
8-32
FC Port Baud Rate
ExpressionLimit
1 set-up
TRUE
-
Uint8
8-33
Parity / Stop Bits
[0] Even Parity, 1 Stop Bit
1 set-up
TRUE
-
Uint8
8-34
Estimated cycle time
0 ms
2 set-ups
TRUE
-3
Uint32
8-35
Minimum Response Delay
10 ms
1 set-up
TRUE
-3
Uint16
8-36
Max Response Delay
ExpressionLimit
1 set-up
TRUE
-3
Uint16
8-37
Max Inter-Char Delay
ExpressionLimit
1 set-up
TRUE
-5
Uint16
8-4* FC MC protocol set
8-40
Telegram selection
[1] Standard telegram 1
2 set-ups
TRUE
-
Uint8
8-41
Parameters for Signals
0
All set-ups
FALSE
-
Uint16
8-42
PCD Write Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-43
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-45
BTM Transaction Command
[0] Off
All set-ups
FALSE
-
Uint8
8-46
BTM Transaction Status
[0] Off
All set-ups
TRUE
-
Uint8
8-47
BTM Timeout
60 s
1 set-up
FALSE
0
Uint16
8-48
BTM Maximum Errors
21 N/A
1 set-up
TRUE
0
Uint8
8-49
BTM Error Log
0.255 N/A
All set-ups
TRUE
-3
Uint32
8-5* Digital/Bus
8-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-51
Quick Stop Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-52
DC Brake Select
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-53
Start Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-54
Reverse Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-57
Profidrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-58
Profidrive OFF3 Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-8* AFD Port Diagnostics
8-80
Bus Message Count
0 N/A
All set-ups
TRUE
0
Uint32
8-81
Bus Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-82
Slave Messages Rcvd
0 N/A
All set-ups
TRUE
0
Uint32
8-83
Slave Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-9* Bus Jog
8-90
Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
67
Uint16
8-91
Bus Jog 2 Speed
ExpressionLimit
All set-ups
TRUE
67
Uint16
Programming
Instruction Manual
MG37A222
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
91
6
6