![background image](http://html1.mh-extra.com/html/danfoss/vlt-automationdrive-fc-301/vlt-automationdrive-fc-301_operating-manual_3414831035.webp)
Type designation
P15K
P18K
P22K
P30K
P37K
High/normal overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
HO
NO
Typical shaft output [kW/(hp)]
15
(20)
18.5
(25)
18.5
(25)
22
(30)
22
(30)
30
(40)
30
(40)
37
(50)
37
(50)
45
(60)
Enclosure protection rating IP20
B4
C3
C3
C4
C4
Enclosure protection rating IP21, IP55, IP66
C1
C1
C1
C2
C2
Output current
Continuous (200–240 V) [A]
59.4
74.8
74.8
88.0
88.0
115
115
143
143
170
Intermittent (60 s overload) (200–240 V) [A]
89.1
82.3
112
96.8
132
127
173
157
215
187
Continuous kVA (208 V) [kVA]
21.4
26.9
26.9
31.7
31.7
41.4
41.4
51.5
51.5
61.2
Maximum input current
Continuous (200–240 V) [A]
54.0
68.0
68.0
80.0
80.0
104
104
130
130
154
Intermittent (60 s overload) (200–240 V) [A]
81.0
74.8
102
88.0
120
114
156
143
195
169
Additional specifications
IP20 maximum cable cross-section
5)
for mains,
brake, motor, and load sharing [mm
2
] ([AWG])
35 (2)
50 (1)
50 (1)
150 (300 MCM) 150 (300 MCM)
IP21, IP55, IP66 maximum cable cross-section
5)
for mains and motor [mm
2
] ([AWG])
50 (1)
50 (1)
50 (1)
150 (300 MCM) 150 (300 MCM)
IP21, IP55, IP66 maximum cable cross-section
5)
for brake and load sharing [mm
2
] ([AWG])
50 (1)
50 (1)
50 (1)
95 (3/0)
95 (3/0)
Maximum cable cross-section
2),5)
for disconnect
[mm
2
] ([AWG])
50, 35, 35 (1, 2, 2)
95, 70, 70
(3/0, 2/0, 2/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
Estimated power loss at rated maximum load
[W]
3)
624
737
740
845
874
1140
1143
1353
1400
1636
Efficiency
4)
0.96
0.97
0.97
0.97
0.97
Table 8.3 Mains Supply 200–240 V, P15K–P37K
Specifications
Operating Guide
MG33AT02
Danfoss A/S © 05/2018 All rights reserved.
33
8
8