Electrical data – VLT® Low Harmonic Drive
and VLT® Advanced Active Filters
44
Danfoss Drives · DKDD.PB.302.A8.02 | Content |
Typecode VLT® Advanced Active Filter
The different VLT® Active Filters can easily be configured according to customer request at
drives.danfoss.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
..
39
A
A
F
0
0
6
A
x
x
x
T
4
E
x
x
H
x
x
G
C
x
x
x
S
.
X
8-10:
190: 190 A correction current
250: 250 A correction current
310: 310 A correction current
400: 400 A correction current
13-15:
E21: IP 21/NEMA 1
E2M: IP 21/NEMA 1 w. mains shield
C2M: IP 21/NEMA 1 w. stainless steel
back-channel and mains shield
E54: IP 54/NEMA 12
E5M: IP 54/NEMA 12 w. mains shield
C5M: IP 54/NEMA 12 w. stainless steel
back-channel and mains shield
16-17:
HX: No RFI Filter
H4: RFI class A1
21:
X: No mains options
3: Disconnect & Fuse
7: Fuse
[T5]
3 x 480 V AC – VLT® Low Harmonic Drive
High overload (150% 1 min/10 min)
Enclosure size
Type
code
Output current
Typical shaft
output power
Conti nuous
input current
Estimated
power loss
Protection rating [IEC/UL]
(3 x 380-440 V)
(3 x 441-480 V)
IP21
IP54
FC-302
Con. I
N
Inter. I
MAX
(60 s)
Con. I
N
Inter. I
MAX
(60 s)
kW @ 400 V
Hp @ 460 V
[A]
[W]
Type 1
Type 12
N132
260
390
240
360
132
200
251
7428
D1n
D1n
N160
315
473
302
453
160
250
304
8048
D2n
D2n
N200
395
593
361
542
200
300
381
9753
D2n
D2n
N250
480
720
443
665
250
350
472
11587
E9
E9
P315
600
900
540
810
315
450
590
14140
E9
E9
P355
658
987
590
885
355
500
647
15286
E9
E9
P400
695
1043
678
1017
400
550
684
16063
E9
E9
[T5]
3 x 480 V AC – VLT® Low Harmonic Drive
Normal overload (110% 1 min/10 min)
Enclosure size
Type
code
Output current
Typical shaft
output power
Conti nuous
input current
Estimated
power loss
Protection rating [IEC/UL]
(3 x 380-440 V)
(3 x 441-480 V)
IP21
IP54
FC-302
Con. I
N
Inter. I
MAX
(60 s)
Con. I
N
Inter. I
MAX
(60 s)
kW @ 400 V
Hp @ 460 V
[A]
[W]
Type 1
Type 12
N132
315
347
302
332
160
250
304
8725
D1n
D1n
N160
395
435
361
397
200
300
381
9831
D2n
D2n
N200
480
528
443
487
250
350
463
11371
D2n
D2n
N250
600
660
540
594
315
450
590
14051
E9
E9
P315
658
724
590
649
355
500
647
15320
E9
E9
P355
745
820
678
746
400
600
733
17180
E9
E9
P400
800
880
730
803
450
600
787
18447
E9
E9
[T4]
3 x 380-480 V AC VLT® Advanced Active Filter
Normal overload (110% 1 min/10min automatically regulated)
Enclosure size
Type
code
Corrected Current
Recommend-
ed fuse and
disconnect*
Estimated
power loss
Protection rating [IEC/UL]
@ 400 V
@ 460 V
@ 480 V
@ 500 V
IP21
IP54
AAF006
Cont.
Int.
Cont.
Int.
Cont.
Int.
Cont.
Int.
[A]
[W]
Type 1
Type 12
A190
260
390
240
360
260
390
240
360
350
5000
D14
D14
A250
315
473
302
453
315
473
302
453
630
7000
E1
E1
A310
395
593
361
542
395
593
361
542
630
9000
E1
E1
A400
480
720
443
665
480
720
443
665
900
11100
E1
E1
* Built-in options for fuses and disconnect recommended