
Ordering typecode for A, B and C enclosures
[1] Application
(character 4-6)
301
VLT® AutomationDrive FC 301
302
VLT® AutomationDrive FC 302
[2] Power size
(character 7-10)
PK25 0.25 kW / 0.33 Hp
PK37 0.37 kW / 0.50 Hp
PK55 0.55 kW / 0.75 Hp
PK75 0.75 kW / 1.0 Hp
P1K1 1.1 kW / 1.5 Hp
P1K5 1.5 kW / 2.0 Hp
P2K2 2.2 kW / 3.0 Hp
P3K0 3.0 kW / 4.0 Hp
P3K7 3.7 kW / 5.0 Hp
P4K0 4.0 kW / 5.5 Hp
P5K5 5.5 kW / 7.5 Hp
P7K5 7.5 kW / 10 Hp
P11K 11 kW / 15 Hp
P15K 15 kW / 20 Hp
P18K 18.5 kW / 25 Hp
P22K 22 kW / 30 Hp
P30K 30 kW / 40 Hp
P37K 37 kW / 50 Hp
P45K 45 kW / 60 Hp
P55K 55 kW / 75 Hp
P75K 75 kW / 100 Hp
P90K 90 kW / 125 Hp
N75K 75 kW / 100 Hp
N90K 90 kW / 125 Hp
[3] AC Line Voltage
(character 11-12)
T2
3 x 200-240 V AC
T4
3 x 380-480 V AC
(FC 301 only)
T5
3 x 380-500 V AC
T6
3 x 525-600 V AC
T7
3 x 525-690 V AC
2)
[4] IP/UL protection ratings
(character 13-15)
IP20 / Chassis enclosures
Z20
IP20/Chassis
(A1 enclosure, FC 301 only)
E20
IP20/Chassis
P20
IP20/C backplate
IP21 / UL Type 1 enclosures
E21
IP21 / Type 1
P21
IP21 / Type 1 + backplate
IP55 / UL Type 12 enclosures
E55
IP55/Type 12
P55
IP55/Type 12 + backplate
Y55
IP55/ Type 12 + backplate
(A4 enclosure, no C-options)
Z55
IP55/Type 12
(A4 enclosure, no C-options)
UL Type 3R enclosures
E3R
UL Type 3R
(North America only)
P3R
UL Type 3R + backplate
(North America only)
IP66 / UL Type 4X enclosures
E66
IP66 / Type 4X
Y66
IP66 / Type 4X + backplate
(A4 enclosure, no C-options)
Z66
IP66 / Type 4X
(A4 enclosure, no C-options)
[5] RFI filter, terminal and monitoring options
– EN/IEC 61800-3
(character 16-17)
H1
RFI-Filter Class A1/B (C1)
H2
RFI-Filter, Class A2 (C3)
H3
RFI-Filter Class A1/B
1)
H4
RFI-Filter, Class A1 (C2)
H5
RFI-Filter, Class A2 (C3)
Marine ruggedized
HX
No RFI-Filter
[6] Braking and safety
(character 18)
X
No brake IGBT
B
Brake IGBT
T
Safe Stop without brake
U
Brake IGBT plus Safe Torque Off
[7] LCP Display
(character 19)
X
Blank faceplate, no LCP installed
N
Numerical Local Control Panel (LCP 101)
G
Graphical Local Control Panel (LCP 102)
[8] PCB Coating –
IEC 721-3-3
(character 20)
X
Standard coated PCB Class 3C2
C
Coated PCB Class 3C3
[9] Mains input
(character 21)
X
No mains option
1
Mains disconnect
(A4, A5, B1, B2, C1 and C2 enclosures only)
8
Mains disconnect and load sharing
(B1, B2, C1 and C2 enclosures only)
D
Load sharing terminals
(B1, B2, C1, C2 enclosures only)
[10] Hardware option A
(character 22)
X
Standard cable entries
O
Metric cable entry (threaded)
S
Imperial cable entry
[11] Hardware option B
(character 23)
X
No adaptation
[12] Special version
(character 24-27)
SXXX Latest released standard software
S067 Integrated Motion Control
[13] LCP language
(character 28)
X
Standard language package including
English, German, French, Spanish, Danish,
Italian, Finnish and others
Contact factory for other language options
[14] A-options: Fieldbus
(character 29-30)
AX
No option
A0
VLT® PROFIBUS DP V1 MCA 101
A4
VLT® DeviceNet MCA 104
A6
VLT® CANopen MCA 105
AT
VLT® 3000 PROFIBUS Converter MCA 113
AU
VLT® 5000 PROFIBUS Converter MCA 114
AL
VLT® PROFINET MCA 120
AN
VLT® EtherNet/IP MCA 121
AQ
VLT® Modbus TCP MCA 122
AY
VLT® POWERLINK MCA 123
A8
VLT® EtherCAT MCA 124
AV
VLT® 5000 DeviceNet Converter MCA 194
[15] B-options
(character 31-32)
BX
No option
BK
VLT® General Purpose MCB 101
BR
VLT® Encoder Input MCB 102
BU
VLT® Resolver Input MCB 103
BP
VLT® Relay Option MCB 105
BZ
VLT® Safety PLC I/O MCB 108
B2
VLT® PTC Thermistor Card MCB 112
B4
VLT® Sensor Input Card MCB 114
B6
VLT® Safety Option MCB 150 TTL
B7
VLT® Safety Option MCB 151 HTL
B8
VLT® Safety Option MCB 152 PROFIsafe STO
[16] C0-option
(character 33-34)
CX
No option
C4
VLT® Motion Control MCO 305
[17] C1-option
(character 35)
X
No C1-ption
R
VLT® Extended Relay Card MCB 113
[18] C1-option software
(character 36-37)
XX
No software option
Note: C4 option in [16] selected with no motion
software in [18] will require programming by
qualified individual
10
VLT® Synchronizing Controller MCO 350
(must select C4 in position [16])
11
VLT® Positioning Controller MCO 351
(must select C4 in position [16])
[19] Control Power Backup Input
(character 38-39)
DX
No DC input installed
D0
VLT® 24 V DC Supply Option MCB 107
D1
VLT® Real-time Clock Option MCB 117
1) Reduced motor cable length
2) Note: T7 drives are not UL certified.
Select T6 for UL certification.
Please beware that not all combinations are possible.
Find help configuring your drive with the online
configurator found under:
driveconfig.danfoss.com
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10] [11] [12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
FC-
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
CX
–
–
XX
–
35
| Content | Danfoss Drives · DKDD.PB.302.A8.02