Pa
r. No.
#
Para
m
ete
r descri
ptio
n
Def
ault value
4-
set-
up
Cha
nge
during
op
era
-
tio
n
Conve
r-
sion inde
x
Type
1
6
-0*
General Stat
us
16-
00
Co
ntrol
Word
0 N
/A
All se
t-
up
s
TRU
E
0
V2
16-
01
Ref
ere
nce [
U
ni
t]
0.0
00 R
efe
rence
Fee
db
ackU
ni
t
All se
t-
up
s
TRU
E
-3
In
t32
16-
02
R
ef
er
ence
[%]
0.
0 %
Al
l set-
up
s
TR
U
E
-1
In
t1
6
16-
03
Stat
us Word
0 N
/A
All se
t-
up
s
TRU
E
0
V2
16-
05
M
ai
n
Actual Value
[%]
0.
00
%
All se
t-
up
s
TRU
E
-2
N
2
16-
09
Custom R
ea
dout
0.
00
Cust
omRea
dou
tUn
it
All se
t-
up
s
TRU
E
-2
In
t32
16-1
*
M
o
tor
Stat
u
s
16-
10
Pow
er [
kW]
0.
00 kW
All se
t-
up
s
TRU
E
1
In
t32
16-
11
Po
we
r [
hp
]
0.
00 hp
Al
l set-
up
s
TR
U
E
-2
In
t3
2
16-
12
Mo
to
r V
olt
ag
e
0.
0 V
All se
t-
up
s
TRU
E
-1
Ui
nt16
16-
13
Fre
qu
ency
0.
0 H
z
All
se
t-
up
s
TRU
E
-1
U
in
t1
6
16-
14
M
otor Curre
nt
0.
00 A
All se
t-
up
s
TRU
E
-2
In
t32
16-
15
Fre
qu
ency [%]
0.
00
%
All se
t-
up
s
TRU
E
-2
N
2
16-
16
Torque
[Nm]
0.
0 N
m
All se
t-
up
s
TRU
E
-1
In
t32
16-
17
Sp
ee
d [
R
PM
]
0 RP
M
Al
l s
et
-up
s
TR
U
E
67
Int
32
16-
18
M
otor Thermal
0 %
All se
t-
up
s
TRU
E
0
Ui
nt8
16-
22
To
rq
ue [%]
0 %
Al
l se
t-u
ps
TRUE
0
In
t1
6
16-3
*
Dr
iv
e
S
tat
us
16-
30
DC
Link Vo
ltag
e
0 V
Al
l set-
up
s
TR
U
E
0
Ui
nt16
16-
32
Brake Ene
rgy /
s
0.
000 kW
All se
t-
up
s
TRU
E
0
Ui
nt32
16-
33
Brake Ene
rgy /
2
m
in
0.
000 kW
Al
l set-
up
s
TR
U
E
0
Ui
nt32
16-
34
Heat
si
nk Temp.
0 °
C
All se
t-
up
s
TRU
E
100
Ui
nt8
16-
35
In
verter Therm
al
0 %
All
se
t-
up
s
TRU
E
0
U
in
t8
16-
36
Inv.
No
m
. Current
Ex
pr
essionLimit
All se
t-
up
s
TRU
E
-2
Ui
nt32
16-
37
In
v. Max.
Cu
rre
nt
Ex
pr
essionLimit
All se
t-u
ps
TRUE
-2
U
in
t32
16-
38
SL Co
ntroll
er
Stat
e
0 N
/A
All se
t-
up
s
TRU
E
0
Ui
nt8
16-
39
Co
ntrol
Card
Temp
.
0 °
C
All se
t-
up
s
TRU
E
10
0
U
in
t8
16-
40
Logg
ing B
uff
er F
ul
l
[0
] N
o
All se
t-
up
s
TRU
E
-
Ui
nt8
16-5* Ref.
& Feed
b.
16-
50
Ex
te
rnal
Ref
ere
nce
0.
0 N/A
All se
t-
up
s
TRU
E
-1
In
t16
16-
52
Fe
ed
ba
ck [Uni
t]
0.
000
P
ro
cessC
tr
lU
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t3
2
16-
53
Digi
Po
t
Ref
ere
nce
0.0
0 N/
A
All se
t-
up
s
TRU
E
-2
In
t16
16-
54
Fe
ed
ba
ck 1
[Uni
t]
0.
000
P
ro
cessC
tr
lU
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t3
2
16-
55
Feed
back 2
[U
nit
]
0.
000
P
ro
cessC
tr
lU
ni
t
All se
t-
up
s
TRU
E
-3
In
t32
16-
56
Fe
ed
ba
ck 3
[Uni
t]
0.
000
P
ro
cessC
tr
lU
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t3
2
16-
58
PID Ou
tput
[%
]
0.
0 %
All se
t-
up
s
TRU
E
-1
In
t16
16-
59
Ad
justed
S
etp
oi
nt
0.
000
P
ro
cessC
tr
lU
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t3
2
5.3.15
Dat
a Readout
s 1
6
-**
5 How to programme the frequency converter
VLT AQUA High Power Operation Instructions
154
MG.20.P3.02 - VLT
®
is a registered Danfoss trademark
5