Pa
r. No. #
Pa
rame
ter de
scri
pt
io
n
Def
ault value
4-
se
t-
up
FC 30
2
on
ly
Cha
nge duri
ng op
-
erat
ion
Co
nver-
sion index
Typ
e
0-0*
B
asi
c
S
et
ti
n
g
s
0-
01
La
ngua
ge
[0] Eng
lish
1 set-
up
TRUE
-
U
int8
0-
02
Mot
or Speed
U
nit
[0] RP
M
2 se
t-up
s
FALS
E
-
Ui
nt8
0-
03
Re
gi
on
al
Setti
ng
s
[0]
Inte
rn
ationa
l
2 set-
ups
FALS
E
-
U
int8
0-
04
O
pe
rati
ng
Stat
e a
t Po
wer-
up
[0
] R
esu
m
e
All se
t-
up
s
TRU
E
-
Ui
nt8
0-
05
Lo
cal
Mode
Unit
[0] As Mo
tor Spe
ed
U
nit
2 se
t-up
s
FALS
E
-
Ui
nt8
0-1*
Set
-u
p
Ope
rat
ion
s
0-
10
Active Se
t-
up
[1
] S
et
-u
p
1
1 set-
up
TRUE
-
U
int8
0-
11
Pr
og
ra
m
m
in
g S
et
-up
[9] Active
Set-
up
All se
t-
up
s
TRU
E
-
Ui
nt8
0-12
Th
is
S
et-
up L
inke
d t
o
[0] Not
linked
Al
l se
t-u
ps
FALS
E
-
U
int8
0-
13
Re
ad
ou
t:
L
ink
ed
S
et-
up
s
0 N
/A
All se
t-
up
s
FALS
E
0
Ui
nt1
6
0-
14
R
eadout: Prog. Set-
ups /
Ch
anne
l
0 N
/A
All se
t-
up
s
TRU
E
0
In
t3
2
0-2*
LCP
Disp
lay
0-
20
Disp
la
y
Line
1.
1 Smal
l
1601
All se
t-
up
s
TRU
E
-
U
in
t16
0-
21
Disp
la
y
Line
1.
2 Smal
l
1662
All se
t-
up
s
TRU
E
-
Ui
nt1
6
0-
22
Disp
la
y
Line
1.
3 Smal
l
1614
Al
l set-
up
s
TR
U
E
-
Ui
nt
16
0-
23
Displ
ay
Line 2 Large
1613
All se
t-
up
s
TRU
E
-
Ui
nt1
6
0-
24
Disp
la
y
Line
3 Large
1652
Al
l set-
up
s
TR
U
E
-
Ui
nt
16
0-
25
My Personal
Menu
Ex
pressionL
imit
1 se
t-up
TRU
E
0
Ui
nt1
6
0-3*
LCP
Cust
om Readou
t
0-
30
Cust
om Re
ado
ut
Unit
[1
] %
All se
t-
up
s
TRU
E
-
Ui
nt8
0-31
Cust
om
Re
ado
ut M
in Va
lue
Ex
pressionL
imit
All se
t-u
ps
TRUE
-2
In
t32
0-
32
Cust
om
Re
ado
ut M
ax
Value
100.
00 Custo
m
R
ead
outUni
t
All se
t-
up
s
TRU
E
-2
In
t3
2
0-
37
Disp
la
y Te
xt 1
0 N
/A
1 se
t-up
TR
UE
0
VisStr[25]
0-
38
Displa
y Text 2
0 N
/A
1 se
t-up
TRU
E
0
Vi
sStr[25]
0-
39
Displa
y Text 3
0 N
/A
1 se
t-up
TRU
E
0
Vi
sStr[25]
0-4*
LCP
Ke
ypad
0-
40
[Han
d on] Ke
y on LCP
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt
8
0-
41
[O
ff]
Ke
y on
LCP
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
0-
42
[Auto o
n] K
ey on LCP
[1] Enabl
ed
Al
l set-
up
s
TR
U
E
-
U
int8
0-
43
[R
ese
t]
Ke
y o
n LCP
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
0-
44
[Off/R
ese
t]
Ke
y o
n LCP
[1]
Enabl
ed
Al
l set-
up
s
TR
U
E
-
U
int8
0-
45
[Drive By
pass] Key
on
LCP
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
0-5*
Co
p
y/Save
0-
50
LCP
Co
py
[0] No
c
op
y
All se
t-
up
s
FALS
E
-
Ui
nt8
0-
51
Set-
up Co
py
[0] No
c
op
y
All se
t-
up
s
FALS
E
-
Ui
nt8
0-6*
Password
0-
60
Main Menu
Pa
ssw
ord
100 N/A
1 se
t-up
TR
UE
0
U
in
t1
6
0-
61
Access to M
ain Menu w/o Pa
sswo
rd
[0
] Full
access
1 se
t-up
TRU
E
-
Ui
nt8
0-
65
Pe
rso
nal
M
enu P
assw
ord
200
N/A
1 se
t-up
TR
UE
0
U
in
t1
6
0-
66
Access
to
Perso
nal Menu
w/o
P
assword
[0
] Full
access
1 se
t-up
TRU
E
-
Ui
nt8
8.3.2.
Operation/
Display 0-**
VLT
®
AQUA Drive
Operating Instructions
8. How to programme the frequency converter
MG.20.M5.02 - VLT
®
is a registered Danfoss trademark
109
8