Normal
o
ver
load 110% for 1 min
u
te
Frequen
cy convert
er
Typical Shaf
t Ou
tput
[kW
]
P110 110
P1
32
13
2
P1
60
160
P200 20
0
P2
50
250
P315 315
P3
55
355
P400 40
0
P450 45
0
Typ
ical Shaft
O
utp
ut [HP
] at 46
0V
150
20
0
250
30
0
350
450
500
55
0
60
0
IP
0
0
D3
D3
D4
D4
D4
E2
E2
E2
E2
IP
21 /
Nema
1
D1
D1
D2
D2
D2
E1
E1
E1
E1
IP
54 /
Ne
ma
12
D1
D1
D2
D2
D2
E1
E1
E1
E1
Ou
tput c
u
rr
ent
Co
nt
in
uo
us (3 x 380-
400 V
) [A]
212
26
0
315
39
5
480
600
658
74
5
80
0
In
te
rmitte
nt
(3 x 38
0-4
00 V
) [A]
233
28
6
347
43
5
528
660
724
82
0
88
0
Co
nt
in
uo
us (3 x
401-
480V
) [A]
190
24
0
302
36
1
443
540
590
67
8
73
0
In
te
rmitte
nt
(3 x
401-
480V
) [A]
209
26
4
332
39
7
487
594
649
74
6
80
3
Cont
in
uo
us kVA (400
VAC) [kVA]
147
18
0
218
27
4
333
416
456
51
6
55
4
Cont
in
uo
us kVA (460
VAC) [kVA]
151
19
1
241
28
8
353
430
470
54
0
58
2
Max. cab
le si
ze:
(mains,
m
oto
r,
br
ake
) [
m
m
2
/ AW
G]
2)
2x7
0
2x2
/0
2x1
85
2x3
50 mcm
4x
240
4x
500 mcm
Max
. i
n
put
curr
ent
Co
nt
in
uo
us (
3 x
3
80-
400
V)
[A]
204
25
1
304
38
1
463
590
647
73
3
78
7
Co
nt
in
uo
us
(3
x 4
01-4
80V
) [A]
183
23
1
291
34
8
427
531
580
66
7
71
8
Max. p
re-fu
ses
1)
[A
]
300
35
0
400
50
0
600
700
900
90
0
90
0
En
vi
ro
nm
en
t
Estim
ated powe
r
lo
ss
at
r
at
ed m
ax.
lo
ad
[W]
4)
3234
3782
4213
5119
5893
763
0
770
1
88
79
94
28
W
ei
ght e
ncl
os
ure
IP00 [kg]
81.
9
90
.5
111.
8
122.
9
137.
7
221
.4
234
.1
23
6.4
27
7.3
We
ig
ht
encl
osure
I
P 21
[kg
]
95.
5
104.
1
125.
4
136.
3
151.
3
263
.2
270
.0
27
2.3
31
3.2
W
ei
ght
en
cl
os
ure IP 54
[kg]
95.
5
104.
1
125.
4
136.
3
151.
3
263
.2
270
.0
27
2.3
31
3.2
Eff
ici
ency
3)
0.
98
0.
98
0.
98
0.
98
0.9
8
0.
98
0.
98
0.
98
0.
98
1)
Fo
r
type of fuse see
section
Fuses
2)
Ameri
can
Wire
Gauge
3)
Me
asure
d u
sing
5 m scree
ned moto
r cabl
es
at
rat
ed
lo
ad
an
d
rate
d
fre
quen
cy
4)
T
he t
ypi
ca
l pow
er
loss
is a
t n
or
m
al
lo
ad
co
nd
iti
on
s a
nd
ex
pec
te
d t
o b
e w
ith
in
+
/-
1
5%
(
tol
er
an
ce
r
ela
te
s
to
var
iet
y
in
vol
tag
e a
nd c
ab
le
co
nd
itio
ns).
Va
lu
es a
re
base
d o
n a
typ
ical
moto
r e
ffi
cien
cy
(
ef
f2
/ef
f3
b
orde
r li
ne
).
Lo
we
r ef
fici
ency
motors
wi
ll al
so a
dd
to
the
pow
er
lo
ss
in
the
frequency con
verte
r and
vi
ce ve
rsa.
If
t
he
sw
itc
hin
g fr
eq
ue
nc
y
is r
ai
sed fr
om
n
om
in
al t
he
pow
er
lo
sses m
ay r
ise
sign
ifi
can
tly.
LCP and
typi
cal
cont
rol
card
p
owe
r
consumptions
are
incl
ude
d.
Furth
er o
ptions a
nd
customer
lo
ad may
add up to
30W to the l
osses
.
(Though ty
pi
call
y only 4W
extra
fo
r a
full
y
lo
ade
d
con
trol
card
, or op
tio
ns for sl
ot A or slo
t B
,
ea
ch)
.
Al
th
ough mea
sureme
nts a
re
m
ade
with
state
o
f th
e a
rt e
quipmen
t,
s
ome measurem
ent
in
ac
cu
racy must
be all
ow
ed f
or (+/- 5%).
10. Specifications
VLT
®
AQUA Drive
Operating Instructions
154
MG.20.M5.02 - VLT
®
is a registered Danfoss trademark
10