
24
MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mains supply 3 x 380/400/415 V
Technical data
Acc. to international VDE and UL/CSA requirements
VLT type 3002 3003
3004
3006
3008
3011 3016
3022 3032 3042
3052
Constant torque (CT):
Output current
I
VLT,N
[A]
2.8
4.1
5.6
10.0
13.0
16.0 24.0
32.0 44.0 61.0
73.0
I
VLT,MAX
[A] (60 s)
3.5
6.5
9.0
16.0
20.8
25.6 38.4
51.2 70.4 97.6 117.0
Output
S
VLT,N
[kVA]
2.0
2.9
4.0
7.2
9.3
11.5 17.2
23.0 31.6 44.0
52.5
S
VLT,MAX
[kVA] (60 s)
2.5
4.6
6.4
11.5
15.0
18.4 27.6
36.8 50.5 70.2
84.1
Typical shaft output
P
VLT,N
[kW]
1.1
1.5
2.2
4.0
5.5
7.5 11.0
15.0 22.0 30.0
37.0
Quadratic torque (VT):
Output current
I
VLT,N
[A]
2.8
4.1
5.6
13.0
16.0
24.0 32.0
44.0 61.0 73.0
88.0
Output
S
VLT,N
[kVA]
2.0
2.9
4.0
9.3
11.5
17.2 23.0
31.6 44.0 52.5
63.3
Typical shaft output
P
VLT,N
[kW]
1.1
1.5
2.2
5.5
7.5
11.0 15.0
22.0 30.0 37.0
45.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0 16.0
16.0 35.0 35.0
50.0
Max. motor cable length
[m]
300, with screened cables: 150 m
Output voltage
U
M
[%]
0-100, of mains voltage
Output frequency
f
M
[Hz]
0-120 or 0-500; programmable
Rated motor voltage
U
M,N
[V]
380/400/415
Rated motor frequency
f
M,N
[Hz]
50/60/87/100
Thermal protection during operation
Integrated thermal motor protection (electronic);
thermistor to DIN 44081
Switching on output
Unlimited (frequent switching on output may result in fault message)
Ramp times
[s]
0.1 - 3600
VLT type 3002 3003
3004
3006
3008
3011 3016
3022 3032 3042
3052
Max. input current
const. load I
L,N
[A]
2.8
4.8
7.0
10.0
13.0
13.8 21.8
30.7 41.9 55.6
66.5
quad. load. I
L,N
[A]
2.8
4.8
7.0
13.0
17.0
22.0 31.0
41.5 57.5 66.5
80.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0 16.0
16.0 35.0 35.0
50.0
Max. pre-fuses
[A] 16.0 16.0
16.0
25.0
25.0
50.0 63.0
63.0 80.0 100
1)
125
1)
Supply voltage
[V]
3 x 380/400/415 ±10% (VDE 0160)
Supply frequency
[Hz]
50/60 Hz
Power factor / cos.
ϕ
1
0.9/1.0
Efficiency
0,96 at 100% load
Switching on input
times/min.
2
VLT type 3002 3003
3004
3006
3008
3011 3016
3022 3032 3042
3052
Weight (kg)
IP 00
7.4
7.4
7.4
12.0
14.0
-
-
-
-
-
-
IP 20
-
-
-
-
-
24.0 26.0
32.0 49.0 54.0
54.0
IP 21
8.0
8.0
8.0
13.0
15.0
-
-
-
-
-
-
IP 54 11.0 11.0
11.0
14.0
15.0
34.0 37.0
48.0 63.0 69.0
69.0
Power loss
CT [W]
60
100
130
195
200
270
425
580
880 1390
1875
at max. load
VT [W]
60
100
130
280
300
425
580
880 1390 1875
2155
Enclosure
VLT type 3002-08: IP 00 / IP 21 / IP 54
VLT type 3011-52: IP 20 / IP 54
Vibration test
[g]
0.7
Relative humidity
[%]
VDE 0160 5.2.1.2.
[°C]
-10
→
+40
-10
→
+45/40 (CT/VT)
Ambient temperature
operation at full load
2)
at full load
2)
(to VDE 0160)
[°C]
-25
→
+65/70,
-25
→
+65/70,
in storage/transport
in storage/transport
EMC standards
Emission
EN 55011, EN 55014, EN 61000-3-2
(See section “EMC test results”) Immunity
EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
1) Only semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the
specifications.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com