135
MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Immunity
In order to document immunity towards
interference from electrical phenomena
external, the following immunity test has
been made on a system consisting of a
VLT
®
frequency converter (with options, if
relevant), a screened control cable and
control box with potentiometer, screened
motor cable and motor.
Fault criteria and test were in accordance
with EN50082-2 and IEC 22G/21/CDV.
The tests were made using the following
standards:
IEC 1000-4-2 (IEC 801-2/1991):
Electrostatic discharges (ESD)
Simulation of electrostatic discharges from
human beings.
IEC 1000-4-3 (IEC 801-3):
Incoming electromagnetic field radia-
tion
Simulation of the effects of radar and radio
communication equipment as well as
mobile communications equipment.
IEC 1000-4-4 (IEC 801-4):
Burst transients
Simulation of interference brought about
by coupling with a contactor, relays or
similar devices.
IEC 1000-4-5:
Surge transients
Simulation of transients brought about e.g.
by lightening that strikes near installations.
ENV50141:
Cable-borne HF
Simulation of the effect of radio transmis-
sion equipment coupled to connection
cables.
VDE0160 class W2 test pulse:
Mains transients
Simulation of high-energy transients
brought about by main fuse breakage,
coupling with phase-compensation
batteries, etc.
VLT
®
3002-3008 380-500V, VLT
®
3002-3004 200V
Line
2kV/5kHz/DCN
2kV/2
4kV/12
-
-
Motor
2kV/5kHz/CCC
-
-
-
-
Brake
2kV/5kHz/CCC
-
-
-
-
Control lines
2kV/5kHz/CCC
-
2kV/2 *
-
-
PROFIBUS option
2kV/5kHz/CCC
-
-
-
-
Signal interface < 3 m
1kV/5kHz/CCC
-
-
-
-
Enclosure
-
-
-
8 kV AD
6 kV CD
10V
Basic specification:
Acceptance criteria according to: IEC 22G/21/CDV, EN50082-2, 175R0740
N
Basic standard
Burst
IEC 1000-4-4
Surge
IEC 1000-4-5
ESD
IEC 1000-4-2
Radiated
tromagn.
IEC 10
Acceptance criterion
B
B
B
A
Port connection
C M
D M
C M
Line
OK
OK
OK
-
-
Motor
OK
-
-
-
-
Brake
OK
-
-
-
-
Control lines
OK
-
OK
-
-
PROFIBUS option
OK
-
-
-
-
Signal interface < 3 m
OK
-
-
-
-
Enclosure
-
-
-
OK
OK
Ω
Ω
Ω
DM:
Differential mode
CM:
Common mode
CCC: Capacitive clamp coupling
DCN: Direct coupling network
* Injection on cable shield
** 2,3 x Û
N
: max. testpulse 1250 V peak