Chapter 5 Function code VFD500 high performance vector control frequency inverter user manual
P04.38
Curve C vertical
axis 4
-100.0%
~
100.0%
100.0%
☆
P04.39
Curve D
horizontal axis 1
0.00V
~
P04.41
0.00V
☆
P04.40
Curve D vertical
axis 1
-100.0%
~
100.0%
0.0%
☆
P04.41
Curve D
horizontal axis 2
P04.39
~
P04.43
3.00V
☆
P04.42
Curve D vertical
axis 2
-100.0%
~
100.0%
30.0%
☆
P04.43
Curve D
horizontal axis 3
P04.41
~
P04.45
6.00V
☆
P04.44
Curve D vertical
axis 3
-100.0%
~
100.0%
60.0%
☆
P04.45
Curve D
horizontal axis 4
P04.43
~
10.00V
10.00V
☆
P04.46
Curve D vertical
axis 4
-100.0%
~
100.0%
100.0%
☆
Description: The range of HDI, AI1 ~ AI4 mapping curve:
➢
For frequency setting, 100% corresponds to the maximum
frequency P01.06.
➢
For torque setting, 100% corresponds to the maximum torque
P14.02.
➢
For other uses, see the description of the relevant function.
Functio
n code
Parameter
name
Description
Default
Propert
y
Note:input less than P04.39,output
decided by curve ten’s digit
P04.41
P04.42
P04.46
P04.43
AI
Corresponding setting
P04.39
P04.40
P04.44
P04.45
58