VFD500 high performance vector control frequency inverter user manual Chapter 5 function code table
P00.06
Source of the
Operation Command
0
:
keypad
1
:
terminal
2
:
communication
➢
Command source: run
、
stop
、
forward
、
reverse
、
jog
、
fast brake stop.etc
➢
If use with DI function, 12
:
Switching run
command to Keypad and 13
:
Switching
run command to Communication,Actuall
effective command source is related with
DI status
0
★
P00.07
Numeric frequency
setting
00.00Hz
~
maximum frequency(Set P21.17=1
to change the unit to 1Rpm)
50.00Hz
☆
P00.08
Rotation direction
0
:
Forward
1
:
Reverse
➢
It is only for keypad control to change
running direction by giving frequency
symbol to be reverse)If command by
keypad/terminal /communication,and not
want to achieve reverse running by
giving frequency symbol to be
reverse,need to change P22.13 in stop
mode(see parameter P22.13)
0
☆
P00.09
Reverse control
0
:
enable
1
:
disbale
0
★
P00.10
Motor option
0
:
motor 1
1
:
motor 2
If use with DI function,16:Switch between
motor 1 and motor 2,Actuall effective
command source is related with DI status
0
★
P00.11
Special industry
0
:
standard drive
1
:
Reserved
0
★
r00.18
Power board software
version
-
-
●
r00.19
Control board software
version
-
-
●
r00.21
SN 1
-
-
●
r00.22
SN 2
-
-
●
Function
code
Parameter name
Description
Default
Property
Function
code
Parameter name
Description
Default
Property
01Group frequency source selction