PVPC plug for external pilot control
Description: Pilot oil supply from another pump.
Location: On the end of the PVP.
Function: Provides a hydraulic pilot supply to the valve stack.
Failure mode
Cause
Corrective action
Main spool moves slow, or not at
all, in all sections
External hydraulic pilot pressure is too low
Check external hydraulic pressure from pilot pump and/or
restrictions
PVPC plug for external pilot
P107 734E
PVPC with check valve
Tee into pressure port
to measure pressure
PVMR Friction Module
Description: Mechanical friction hold.
Location: Mounted on main spool in the PVB.
Function: Infinite mechanical positioning of the main spool.
Failure mode
Cause
Corrective action
Flow changes
Excessive flow across the main spool
Reduce flow (100 l/min or less)
Vibration
Reduce vibration
Broken spring
Replace broken springs
Flow changes or will not stay in
detent
Check for proper assembly of parts
Install parts correctly per specification sheet
Service Manual
PVG 32 Proportional Valve Group
PVG 32 Component Troubleshooting