Checking input control signal:
1. Install volt meter to ground pin connection and signal pin with PVE in circuit.
2. Turn the power on for the electrical controller.
3. Actuate the electrical controller and read the voltage.
4. The control voltage should be per the electrical controller output signal.
On electrical actuators - coil resistance can not be measured at the pins.
When replacing an electrical actuator be sure that it has the same part number on it to ensure original
functionality.
If filter in the electrical actuator has pieces of contamination trapped in it, this is a good indication that
the complete system is contaminated and needs to be flushed. The filter in the electrical actuator can be
removed and cleaned.
PVEO ON/OFF electrical actuator
Description: ON/OFF electrical actuator.
Location: On the end of the main spool of the PVB.
Function: Convert an electrical command to move the main spool to a set position.
Troubleshooting
Failure mode
Cause
Corrective action
Does not work in either direction
No control voltage from the electrical
controller
Check voltage from the electrical controller
Resistance check (measures between pin 2 and ground):
17 OHMs for 12 volt systems
63 OHMs for 24 volt systems
Command pin wire in mating connector is
broken
Repair broken wire
Connector corroded
Replace PVE and mating connector
This condition is caused by water ingression or ground connection
24 volt electrical actuator used on a 12 volt
system
Replace with the correct electrical actuator for a 24 volt system
No power from the battery
Check power to electrical actuator
Power pin wire in mating connector is broken Repair broken wire
Ground connection must be hard wired
straight from the battery or from the electrical
controller
Repair ground connection
Works in one direction
(Assuming that the manual control
lever and the main spool moves
freely both directions)
No control voltage from the electrical
controller
Check voltage from the electrical controller is there for that
direction
Lack of voltage to actuator
(Minimum voltage 11 volts for 12 volt system
and 22 volts for 24 volt system)
Check system voltage
Electrical actuator is defective
Replace electrical actuator per spec. on the valve
Works intermittently
Loose connection between the electrical
actuator and controller
Repair connector
Electrical actuator is defective
Replace electrical actuator per spec. on the valve
Short in wiring harness
Repair wiring harness
Works with no command from
controller
Fine contamination
Replace the electrical actuator per valve spec. and flush the
complete system and fill with filtered oil
Short in wiring harness
Repair wiring harness