Cause
Check
Corrective action
Main spool position feedback
transducer signal incorrect
Check feedback pin for damage
Replace PVE
Contamination in hydraulic oil
Take oil sample
Flush complete system.
Fill reservoir with clean filtered fluid per OEM
specification
Air in hydraulic pilot lines
Check for air trapped in signal lines from the
controller to the valve section module
Bleed air from the hose connection at the valve section
Hydraulic remote actuator faulty
Check signal pressure from the remote hydraulic
controller
Repair or replace cylinder/motor
Low hydraulic oil supply
Check fluid level in reservoir
Fill reservoir with clean filtered fluid per OEM
specification
Hydraulic oil supply
Cause
Check
Corrective action
Pump not running
Check prime mover for operation
Repair or replace prime mover
Check condition of drive coupling
Repair or replace drive coupling
Insufficient oil in reservoir
Check fluid level in reservoir
Fill with clean filtered oil
Leaking or burst supply hose
Inspect lines to valve stack
Repair or replace damaged hose
Relief valve malfunction
Check for contamination and operation of relief valve Repair or replace relief valve
Isolating valves are closed
Check that all isolating valves are open and clear
Faulty pump control
Check pump compensator for correct operation and
setting per pump manufacturers
Repair or replace pump compensator per pump
manufacturers recommendations
Low standby pressure in PVP - open
center pump
Check idle standby pressure - 10 Bar [145 PSI]
Replace
Check condition of compensator spool spring
Replace module due to worn components
Low standby pressure in pump
control - variable pump
Check pump LS control for operation and setting
Stand by pressure should be 15 bar [220 psi]
minimum
Repair or replace LS control per pump manufacturers
procedures
PVP pressure relief valve faulty
Check pressure relief valve spool and spring for
freedom of operation
Replace
PVP orifices blocked
Check PVP orifices for blockage
Remove blockage
Internal filters blocked
Check for blockage in internal filters
Remove blockage
Supply lines blocked
Inspect supply lines for blockages
Remove blockage
Internal hydraulic pilot pressure
insufficient
Inspect pilot oil pressure reducing valve for proper
operation
Repair or replace
Blocked LS galleries
Check LS galleries for blockage
Clean blockage from LS galleries
Shuttle valves faulty
Check LS system shuttle valves for wear and damage
Replace as needed
Check for contamination per specification HPP 030.
Refer to Design Guideline for Hydraulic Fluid
Cleanliness, Technical Information Manual
520L0467. If fluid is out of spec., flush hydraulic system and fill
with clean filtered oil.
Electrical supply
Cause
Check
Corrective action
No electrical power
Check electrical circuit
Repair as needed
Verify emergency stop switch is in the proper operating position
Reset
Neutral position switch faulty
Check operation of neutral position switch in remote controller (if
connected in circuit) PVRE/PVRES/PVREL
Replace switch
Service Manual
PVG 32 Proportional Valve Group
System Troubleshooting
18 |
©
Danfoss | February 2017
11039167 | AX00000031en-US0301