![Danfoss PVG 32 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/danfoss/pvg-32/pvg-32_service-manual_507226040.webp)
Checking input control signal
1. Install a volt meter to the ground pin connection and to the signal pin.
2. Turn the power on for the electrical controller.
3. Actuate the electrical controller and read the voltage.
4. The control voltage should be per the electrical controller output range.
PVE Series 4/7 Connectors
PVEO/PVEO-R/PVEO-HP
Connector
Pin 1
Pin 2
Pin 3
Pin 4
1x4 AMP
Udc_A
Udc_B
GND
GND
1x4 DEU
Udc_A
GND
GND
Udc_B
1x4 DIN
Udc_A
Udc_B
GND
PVEO-DI
Connector
Pin 1
Pin 2
Pin 3
Pin 4
2x4 AMP (A)
Udc_A
Udc_B
GND
GND
2x4 AMP (B)
DI-B
DI-A
GND
Udc
2
PVEM
Connector
Pin 1
Pin 2
Pin 3
Pin 4
1x4 DIN
Udc
Us
Error
GND
PVEA/PVEH/PVES
Connector
Pin 1
Pin 2
Pin 3
Pin 4
1x4 AMP
Us
Udc
GND
Error
1x4 DEU
Us
Error
GND
Udc
1x4 DIN
Udc
Us
Error
GND
PVEA-DI/PVEH-DI
Connector
Pin 1
Pin 2
Pin 3
Pin 4
2x4 AMP (A)
Us
Udc
GND
Error
2x4 AMP (B)
DI-A
DI-B
GND
Udc
2
2x4 DEU (A)
Us
Error
GND
Udc
2x4 DEU (B)
Udc
2
GND
DI-A
DI-B
PVEH-FLA
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
1x6 AMP
Us
Udc
GND
Error
Float
1x6 DEU
Us
Error
Float
GND
Udc
PVEH-SP/PVES-SP
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
1x6 DEU
Us
Error
SP
GND
Udc
Service Manual
PVG 32 Proportional Valve Group
PVG 32 Component Troubleshooting
40 |
©
Danfoss | February 2017
11039167 | AX00000031en-US0301