Cylinder/motor responds in one direction only
Cause
Check
Corrective action
Verify if fault is mechanical, electrical
or hydraulic
Operate manual lever in both directions to confirm if
mechanical or electrical or hydraulic
If moving the manual lever operates the cylinder/motor
in both directions check electrical or hydraulic
If operating the manual lever strokes the cylinder/
motor in one direction only, check manual stop screw
adjustment
Back out manual stop on manual controller and torque
the jam not to 8 Nm [70 lbf•in] Do not exceed maximum
torque
Check movement of manual lever when electrical
controller is operated
If manual lever does not move in one direction check
electrical signal from controller and wiring at the PVE
module
Check movement of manual lever when hydraulic
controller is operated
If manual lever does not move in both directions check
hydraulic pressure at the PVG module
Air in system
Entrained air generates heat under pressure
Look for foam or bubbles in reservoir. Check for leaks on
inlet side of charge pump.
Internal leakage
Excessive internal leakage may overheat the system.
Install loop flushing defeat option and monitor case flow.
If case flow is excessive, motor may require major repair.
Contact Danfoss Service.
Shock valves
Swap and see if problem follows
Replace valves
Solenoid actuation
If power is OK from controller
Repair wiring to PVE module
Main spool travel restricted
Stop on manual controller turned in too far
Back out manual stop on manual controller
Remote electrical controller
Insufficient signal from electrical controller
Repair or replace electrical controller
PVEO connections
Incorrect PVE/PVEO connections
Connect correct way
Remote hydraulic controller PVRH
Insufficient pilot oil pressure from remote hydraulic
controller Pressure needs to be 25 Bar [360 psi]
Repair or replace remote hydraulic controller
Main valve spool moves without oil passing to cylinder/motor
Cause
Check
Corrective action
Insufficient oil supply to valve
Check the pump per manufacturers procedure
Repair or replace pump per manufacturers procedure
Optional pressure compensator in
valve section not functioning
Check compensator spool
Replace spool
Insufficient load pressure at
compensator spring chamber
LS drilling holes plugged
Clean or replace
Cylinder/motor load too high for
pressure setting of the system
Check pressure at the valve
If pressure is set to spec. per valve lower load on cylinder/
motor
Blocked LS galleries
Inspect for blockage in LS galleries
Remove blockage in LS galleries
Shuttle valve faulty
Inspect shuttle valve
Repair or replace
Blocked LS lines to pump controller
Inspect LS lines from PCG to pump controller
Remove blockage in LS lines from the PVG valve to pump
controller
Oil bypassing at shock valve/anti-
cavitation check valve
Check if stuck open or damaged
Replace valve
Internal leakage in cylinder/motor
Inspect for by-passing of oil per cylinder/motor
manufacture per manufactures procedure
Repair or replace cylinder/motor per manufactures
procedure
Too much leakage in LS spool in pump
control
Check bleed orifice in LS control
Use a LS pump control with no bleed orifice
Blocked thermal orifice
check thermal orifice (blocked)
Replace thermal orifice
Load too high for system
Check for proper system pressure
Adjust pressure to valve specification
Internal leakage in cylinder/motor
Inspect for bypassing of oil per cylinder/motor
manufacturer specification
Repair or replace cylinder/motor
Shock valve or anti-cavitation check
valve faulty
Inspect for damage and contamination
Repair or replace cylinder/motor
System relief valve pressure set too low
for load
Install pressure gauge and check pressure
Adjust pressure to system specification
Lower load
Service Manual
PVG 32 Proportional Valve Group
System Troubleshooting
16 |
©
Danfoss | February 2017
11039167 | AX00000031en-US0301